Vol. 84, Issue 2, 553-561, February 1998
Unité 14 de Physiopathologie Respiratoire, Institut National de la Santé et de la Recherche Médicale, Université H. Poincaré Nancy I, 54500 Vandoeuvre-les-Nancy, France
Peslin, R., and C. Duvivier. Partitioning of airway and
respiratory tissue mechanical impedances by body plethysmography. J. Appl. Physiol. 84(2): 553-561, 1998.
We have tested the feasibility of separating the airway (Zaw)
and tissue (Zti) components of total respiratory input impedance
(Zrs,in) in healthy subjects by measuring alveolar gas compression by
body plethysmography (Vpl) during pressure oscillations at the airway
opening. The forced oscillation setup was placed inside a body
plethysmograph, and the subjects rebreathed
BTPS gas. Zrs,in and the relationship between Vpl and airway flow (Hpl) were measured from 4 to 29 Hz. Zaw
and Zti were computed from Zrs,in and Hpl by using the monoalveolar T-network model and alveolar gas compliance derived from thoracic gas
volume. The data were in good agreement with previous observations: airway and tissue resistance exhibited some positive and negative frequency dependences, respectively; airway reactance was consistent with an inertance of 0.015 ± 0.003 hPa · s2 · l
1
and tissue reactance with an elastance of 36 ± 8 hPa/l. The changes seen with varying lung volume, during elastic loading of the chest and
during bronchoconstriction, were mostly in agreement with the expected
effects. The data, as well as computer simulation, suggest that the
partitioning is unaffected by mechanical inhomogeneity and only
moderately affected by airway wall shunting.
respiratory mechanics; methods; forced oscillations; alveolar pressure; airway impedance; tissue impedance
This article has been cited by other articles:
![]() |
M. K. Johnson, M. Birch, R. Carter, J. Kinsella, and R. D. Stevenson Use of reactance to estimate transpulmonary resistance Eur. Respir. J., June 1, 2005; 25(6): 1061 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Bijaoui, P. F. Baconnier, and J. H. T. Bates Mechanical output impedance of the lung determined from cardiogenic oscillations J Appl Physiol, August 1, 2001; 91(2): 859 - 865. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.M. Lorino, F. Lofaso, E. Dahan, A. Harf, and H. Lorino Respiratory impedance response to continuous negative airway pressure in awake controls and OSAS Eur. Respir. J., January 1, 2001; 17(1): 71 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Peslin and C. Duvivier Evaluation of a forced oscillation method to measure thoracic gas volume J Appl Physiol, March 1, 1998; 84(3): 862 - 867. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |