Journal of Applied Physiology AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 83: 1775, 1997;
8750-7587/97 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seale, J. L.
Right arrow Articles by Rumpler, W. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seale, J. L.
Right arrow Articles by Rumpler, W. V.

Vol. 83, Issue 5, 1775-1775, 1997


SPECIAL COMMUNICATION
Synchronous direct gradient layer and indirect room calorimetry

James L. Seale and William V. Rumpler

Diet and Human Performance Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, US Department of Agriculture, Beltsville, Maryland 20705

Received 5 August 1996; accepted in final form 21 July 1997.

Rumpler, James L., and William V. Seale. Synchronous direct gradient layer and indirect room calorimetry. J. Appl. Physiol. 83(5): 1775-1781, 1997.---A dual direct/indirect room-sized calorimeter is used at the Beltsville Human Nutrition Research Center to measure heat emission and energy expenditure in humans. Because the response times of a gradient layer direct calorimeter and an indirect calorimeter are not equivalent, the respective rate of heat emission and energy expenditure cannot be directly compared. A system of equations has been developed and tested that can correct the respective outputs of the direct gradient layer calorimeter and indirect calorimeter for delays due to the response times of the measurement systems. Performance tests using alcohol combustion to simulate a human subject indicate accurate measurements of heat production from indirect (99.9 ± 0.4%), indirect corrected for response time (99.9 ± 0.5%), direct (99.9 ± 0.8%), and direct corrected for response time (99.9 ± 0.8%) calorimetry systems. Results from 24-h measurements in 10 subjects indicate that corrected heat emission is equivalent to (99.8 ± 2.0%) corrected energy expenditure. However, heat emission measured during sleep was significantly greater (14%) than energy expenditure, suggesting a change in the energy stored as heat in the body. This difference was reversed during the day. These results illustrate how the simultaneous measurement of heat emission and energy expenditure provides insights into heat regulation.

heat emission; heat production; energy expenditure





This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
K. J. Kaiyala and D. S. Ramsay
Assessment of heat production, heat loss, and core temperature during nitrous oxide exposure: a new paradigm for studying drug effects and opponent responses
Am J Physiol Regulatory Integrative Comp Physiol, March 1, 2005; 288(3): R692 - R701.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online