Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 83: 1762-1767, 1997;
8750-7587/97 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Adler, A.
Right arrow Articles by Berthiaume, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Adler, A.
Right arrow Articles by Berthiaume, Y.

Vol. 83, Issue 5, 1762-1767, 1997


SPECIAL COMMUNICATION
Monitoring changes in lung air and liquid volumes with electrical impedance tomography

A. Adler1,2, R. Amyot3, R. Guardo1, J. H. T. Bates2, and Y. Berthiaume3

3 Centre de Recherche Hôtel-Dieu de Montréal and Department of Medicine, Université de Montréal, 1 Institut de Génie Biomédical, École Polytechnique, and 2 Meakins-Christie Laboratories and Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada H2W 1T8

Received 11 February 1997; accepted in final form 25 June 1997.

Adler, A., R. Amyot, R. Guardo, J. H. T. Bates, and Y. Berthiaume. Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J. Appl. Physiol. 83(5): 1762-1767, 1997.---Electrical impedance tomography (EIT) uses electrical measurements at electrodes placed around the thorax to image changes in the conductivity distribution within the thorax. This technique is well suited to studying pulmonary function because the movement of air, blood, and extravascular fluid induces significant conductivity changes within the thorax. We conducted three experimental protocols in a total of 19 dogs to assess the accuracy with which EIT can quantify changes in the volumes of both gas and fluid in the lungs. In the first protocol, lung volume increments from 50 to 1,000 ml were applied with a large syringe. EIT measured these volume changes with an average error of 27 ± 6 ml. In the second protocol, EIT measurements were made at end expiration and end inspiration during regular ventilation with tidal volume ranging from 100 to 1,000 ml. The average error in the EIT estimates of tidal volume was 90 ± 43 ml. In the third protocol, lung liquid volume was measured by instilling 5% albumin solution into a lung lobe in increments ranging from 10 to 100 ml. EIT measured these volume changes with an average error of 10 ± 10 ml and was also able to detect into which lobe the fluid had been instilled. These results indicate that EIT can noninvasively measure changes in the volumes of both gas and fluid in the lungs with clinically useful accuracy.

lung water; lung volume; thoracic impedance


0161-7567/97 $5.00 Copyright © 1997 the American Physiological Society




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J. A. Victorino, J. B. Borges, V. N. Okamoto, G. F. J. Matos, M. R. Tucci, M. P. R. Caramez, H. Tanaka, F. S. Sipmann, D. C. B. Santos, C. S. V. Barbas, et al.
Imbalances in Regional Lung Ventilation: A Validation Study on Electrical Impedance Tomography
Am. J. Respir. Crit. Care Med., April 1, 2004; 169(7): 791 - 800.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Hinz, P. Neumann, T. Dudykevych, L. G. Andersson, H. Wrigge, H. Burchardi, and G. Hedenstierna
Regional Ventilation by Electrical Impedance Tomography: A Comparison With Ventilation Scintigraphy in Pigs
Chest, July 1, 2003; 124(1): 314 - 322.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Adler, N. Shinozuka, Y. Berthiaume, R. Guardo, and J. H. T. Bates
Electrical impedance tomography can monitor dynamic hyperinflation in dogs
J Appl Physiol, February 1, 1998; 84(2): 726 - 732.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online