Journal of Applied Physiology AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 83: 1242-1255, 1997;
8750-7587/97 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kenyon, C. M.
Right arrow Articles by Macklem, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kenyon, C. M.
Right arrow Articles by Macklem, P. T.

Journal of Applied Physiology
Vol. 83, No. 4, pp. 1242-1255, October 1997
EXERCISE AND MUSCLE

Rib cage mechanics during quiet breathing and exercise in humans

C. M. Kenyon1, S. J. Cala1, S. Yan2, A. Aliverti3, G. Scano4, R. Duranti4, A. Pedotti3, and Peter T. Macklem1

1 Meakins-Christie Laboratories, McGill University, and 2 Montréal Chest Institute, Montreal, Quebec, Canada H2X 2P4; 3 Politecnico di Milano, Dipartimento di Bioingegneria, Centro di Bioingegneria, Milan; and 4 First Clinica Medica III, Università di Firenze, Florence, Italy

Received 24 July 1996; accepted in final form 17 April 1997.

Kenyon, C. M., S. J. Cala, S. Yan, A. Aliverti, G. Scano, R. Duranti, A. Pedotti, and Peter T. Macklem. Rib cage mechanics during quiet breathing and exercise in humans. J. Appl. Physiol. 83(4): 1242-1255, 1997.---During exercise, large pleural, abdominal, and transdiaphragmatic pressure swings might produce substantial rib cage (RC) distortions. We used a three-compartment chest wall model (J. Appl. Physiol. 72: 1338-1347, 1992) to measure distortions of lung- and diaphragm-apposed RC compartments (RCp and RCa) along with pleural and abdominal pressures in five normal men. RCp and RCa volumes were calculated from three-dimensional locations of 86 markers on the chest wall, and the undistorted (relaxation) RC configuration was measured. Compliances of RCp and RCa measured during phrenic stimulation against a closed airway were 20 and 0%, respectively, of their values during relaxation. There was marked RC distortion. Thus nonuniform distribution of pressures distorts the RC and markedly stiffens it. However, during steady-state ergometer exercise at 0, 30, 50, and 70% of maximum workload, RC distortions were small because of a coordinated action of respiratory muscles, so that net pressures acting on RCp and RCa were nearly the same throughout the respiratory cycle. This maximizes RC compliance and minimizes the work of RC displacement. During quiet breathing, plots of RCa volume vs. abdominal pressure were to the right of the relaxation curve, indicating an expiratory action on RCa. We attribute this to passive stretching of abdominal muscles, which more than counterbalances the insertional component of transdiaphragmatic pressure.

respiratory kinematics; respiratory muscles; rib cage distortions; rib cage bending stiffness; diaphragm


0161-7567/97 $5.00 Copyright © 1997 the American Physiological Society




This article has been cited by other articles:


Home page
Eur Respir JHome page
A. Aliverti, M. Quaranta, B. Chakrabarti, A. L. P. Albuquerque, and P. M. Calverley
Paradoxical movement of the lower ribcage at rest and during exercise in COPD patients
Eur. Respir. J., January 1, 2009; 33(1): 49 - 60.
[Abstract] [Full Text] [PDF]


Home page
ERRHome page
P. T. Macklem
Circulatory effects of expiratory flow-limited exercise, dynamic hyperinflation and expiratory muscle pressure
Eur. Respir. Rev., December 1, 2006; 15(100): 80 - 84.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. E. Finucane, J. A. Panizza, and B. Singh
Efficiency of the normal human diaphragm with hyperinflation
J Appl Physiol, October 1, 2005; 99(4): 1402 - 1411.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. L. Dellaca, L. D. Black, H. Atileh, A. Pedotti, and K. R. Lutchen
Effects of posture and bronchoconstriction on low-frequency input and transfer impedances in humans
J Appl Physiol, July 1, 2004; 97(1): 109 - 118.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
A Aliverti, N Stevenson, R L Dellaca, A Lo Mauro, A Pedotti, and P M A Calverley
Regional chest wall volumes during exercise in chronic obstructive pulmonary disease
Thorax, March 1, 2004; 59(3): 210 - 216.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. Bianchi, F. Gigliotti, I. Romagnoli, B. Lanini, C. Castellani, M. Grazzini, and G. Scano
Chest Wall Kinematics and Breathlessness During Pursed-Lip Breathing in Patients With COPD
Chest, February 1, 2004; 125(2): 459 - 465.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Filippelli, R. Duranti, F. Gigliotti, R. Bianchi, M. Grazzini, L. Stendardi, and G. Scano
Overall Contribution of Chest Wall Hyperinflation to Breathlessness in Asthma
Chest, December 1, 2003; 124(6): 2164 - 2170.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Singh, J. A. Panizza, and K. E. Finucane
Breath-by-breath measurement of the volume displaced by diaphragm motion
J Appl Physiol, March 1, 2003; 94(3): 1084 - 1091.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Aliverti, G. Ghidoli, R. L. Dellaca, A. Pedotti, and P. T. Macklem
Chest wall kinematic determinants of diaphragm length by optoelectronic plethysmography and ultrasonography
J Appl Physiol, February 1, 2003; 94(2): 621 - 630.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C.-L. Que, C. Kolmaga, L.-G. Durand, S. M. Kelly, and P. T. Macklem
Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary results
J Appl Physiol, October 1, 2002; 93(4): 1515 - 1526.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Singh, P. R. Eastwood, and K. E. Finucane
Volume displaced by diaphragm motion in emphysema
J Appl Physiol, November 1, 2001; 91(5): 1913 - 1923.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. A. Otte, E. Oostveen, R. H. Geelkerken, A. B. J. Groeneveld, and J. J. Kolkman
Exercise induces gastric ischemia in healthy volunteers: a tonometry study
J Appl Physiol, August 1, 2001; 91(2): 866 - 871.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. ALIVERTI, R. DELLACÁ, P. PELOSI, D. CHIUMELLO, A. PEDOTTI, and L. GATTINONI
Optoelectronic Plethysmography in Intensive Care Patients
Am. J. Respir. Crit. Care Med., May 1, 2000; 161(5): 1546 - 1552.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
R. Chen, B. Kayser, S. Yan, and P. T. Macklem
Twitch transdiaphragmatic pressure depends critically on thoracoabdominal configuration
J Appl Physiol, January 1, 2000; 88(1): 54 - 60.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Sanna, F. Bertoli, G. Misuri, F. Gigliotti, I. Iandelli, M. Mancini, R. Duranti, N. Ambrosino, and G. Scano
Chest wall kinematics and respiratory muscle action in walking healthy humans
J Appl Physiol, September 1, 1999; 87(3): 938 - 946.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. GORINI, I. IANDELLI, G. MISURI, F. BERTOLI, M. FILIPPELLI, M. MANCINI, R. DURANTI, F. GIGLIOTTI, and G. SCANO
Chest Wall Hyperinflation during Acute Bronchoconstriction in Asthma
Am. J. Respir. Crit. Care Med., September 1, 1999; 160(3): 808 - 816.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
A. Aliverti, S. J. Cala, R. Duranti, G. Ferrigno, C. M. Kenyon, A. Pedotti, G. Scano, P. Sliwinski, P. T. Macklem, and S. Yan
Human respiratory muscle actions and control during exercise
J Appl Physiol, October 1, 1997; 83(4): 1256 - 1269.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
I. Iandelli, A. Aliverti, B. Kayser, R. Dellaca, S. J. Cala, R. Duranti, S. Kelly, G. Scano, P. Sliwinski, S. Yan, et al.
Determinants of exercise performance in normal men with externally imposed expiratory flow limitation
J Appl Physiol, May 1, 2002; 92(5): 1943 - 1952.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Aliverti, I. Iandelli, R. Duranti, S. J. Cala, B. Kayser, S. Kelly, G. Misuri, A. Pedotti, G. Scano, P. Sliwinski, et al.
Respiratory muscle dynamics and control during exercise with externally imposed expiratory flow limitation
J Appl Physiol, May 1, 2002; 92(5): 1953 - 1963.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online