Journal of Applied Physiology AJP: Cell Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 82: 983-987, 1997;
8750-7587/97 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Young, S. S.
Right arrow Articles by Viel, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Young, S. S.
Right arrow Articles by Viel, L.

Journal of Applied Physiology
Vol. 82, No. 3, pp. 983-987, March 1997
GAS EXCHANGE, MECHANICS, AND AIRWAYS

Frequency dependence of forced oscillatory respiratory mechanics in horses with heaves

S. S. Young, D. Tesarowski, and L. Viel

Department of Clinical Studies, University of Guelph, Guelph, Ontario, Canada N1G 2W1

Received 20 June 1996; accepted in final form 22 October 1996.

Young, S. S., D. Tesarowski, and L. Viel. Frequency dependence of forced oscillatory respiratory mechanics in horses with heaves. J. Appl. Physiol. 82(3): 983-987, 1997.---The effect of measurement frequency on respiratory mechanics was investigated in six horses with reversible allergic airway disease. Total respiratory impedance was measured at 1.5, 2.0, 3.0, and 5.0 Hz by using the forced oscillation technique with the horses in remission, after acute antigenic challenge producing clinical heaves, and with heaves but after the administration of 2 mg fenoterol by inhalation. The slopes of the magnitude (|Zrs|) and real part (R) of total respiratory impedance over the frequency range 1.5-3 Hz changed significantly after antigenic challenge and fenoterol. The ratio of R at 2 Hz to R at 3 Hz, however, discriminated better among the three conditions. Compliance and resonant frequency (calculated by using a three-element model) changed significantly after antigenic challenge and fenoterol, but inertance did not. We concluded that horses with heaves showed frequency dependence of R and |Zrs| at frequencies up to 3 Hz and that parameters derived from a three-element model were useful indicators of small airway obstruction in the horse.

resistance; compliance; inertance; resonant frequency; airway obstruction


0161-7567/97 $5.00 Copyright © 1997 the American Physiological Society




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
C. M. Deaton, L. Deaton, E. Jose-Cunilleras, T. L. Vincent, A. W. Baird, K. Dacre, and D. J. Marlin
Early onset airway obstruction in response to organic dust in the horse
J Appl Physiol, March 1, 2007; 102(3): 1071 - 1077.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Horan, S. Mateus, P. Beraldo, L. Araujo, J. Urschel, E. Urmenyi, and F. Santiago
Forced Oscillation Technique to Evaluate Tracheostenosis in Patients With Neurologic Injury
Chest, July 1, 2001; 120(1): 69 - 73.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online