Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 81: 1423-1429, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nelin, L. D.
Right arrow Articles by Dawson, C. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nelin, L. D.
Right arrow Articles by Dawson, C. A.

Journal of Applied Physiology, Vol 81, Issue 3 1423-1429, Copyright © 1996 by American Physiological Society


ARTICLES

Electrochemical nitric oxide and nitrogen dioxide analyzer for use with inhaled nitric oxide

L. D. Nelin, N. T. Christman, J. F. Morrisey and C. A. Dawson
Department of Pediatrics, Medical College of Wisconsin, Milwaukee 53226, USA.

The use of inhaled nitric oxide (NO) in research and clinical applications requires the monitoring of NO and its autooxidation product nitrogen dioxide (NO2) in inspired gas and in the ambient environment. We describe an inexpensive electrochemical NO and NO2 analyzer that uses a critical orifice constant-flow controller and a microprocessor crossover correction for the measurement of NO and NO2 in the concentration range relevant to the use of inhaled NO. The analyzer proved to have good accuracy and precision for NO and NO2 in the range of concentrations relevant to studies of inhaled NO. In this range, the performance was similar to that of a chemiluminescence analyzer, and the response characteristics were not affected by varying the O2 concentration of the mixtures analyzed.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. Earley, L. D. Nelin, L. G. Chicoine, and B. R. Walker
Hypoxia-induced pulmonary endothelin-1 expression is unaltered by nitric oxide
J Appl Physiol, March 1, 2002; 92(3): 1152 - 1158.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Parviz, M. Bousamra II, J. H. Chammas, E. K. Birks, K. W. Presberg, E. R. Jacobs, and L. D. Nelin
Effects of chronic pulmonary overcirculation on pulmonary vasomotor tone
Ann. Thorac. Surg., February 1, 1999; 67(2): 522 - 527.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online