Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 80: 1880-1890, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coughlin, M. F.
Right arrow Articles by Stamenovic, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coughlin, M. F.
Right arrow Articles by Stamenovic, D.

Journal of Applied Physiology, Vol 80, Issue 6 1880-1890, Copyright © 1996 by American Physiological Society


ARTICLES

Dynamic behavior of lung parenchyma in shear

M. F. Coughlin, B. Suki and D. Stamenovic
Department of Biomedical Engineering, Boston University, Massachusetts 02215, USA.

Dynamic shear properties of excised rabbit lungs were studied by measuring creep deformation after application of a step indentation force to the pleural surfaces by a rigid cylindrical punch. The punch diameter was 9.5 mm, and punch forces were 2,4, and 6 g. Measurements were made at lung volumes of 40, 60, and 90% of the total lung capacity before and after lavage with 3-dimethyl siloxane, which provided a constant surface tension of 16 dyn/cm at the alveolar surfaces. A power-law model was fitted to creep data and then transformed into the frequency (f) domain by using Laplace transforms. The optimum model parameters were used to calculate shear elastance (E mu), shear resistance (R mu), and shear hysteresivity (2 pi fR mu/E mu) between 0.01 and 2.0 Hz. It was found that E mu slightly increased and R mu decreased nearly hyperbolically with increasing f, both decreased with increasing indentation force, and both increased with increasing mean lung volume. Shear hysteresivity decreased sharply from 0.01 to 0.25 Hz and then assumed a nearly steady value that was an order of magnitude lower than the value reported previously for uniformly oscillated lungs. Changes in E mu and R mu after lavage were correlated with changes in transpulmonary pressure and not with changes in surface film properties. These results suggest that in the breathing range of frequencies 1) the energy loss of lung parenchyma is a much smaller fraction of the stored elastic energy in shear than in uniformly oscillated lungs and 2) transpulmonary pressure, not dynamic properties of surface film, is the primary determinant of lung dynamic properties in shear.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
F. G. Salerno and M. S. Ludwig
Elastic moduli of excised constricted rat lungs
J Appl Physiol, January 1, 1999; 86(1): 66 - 70.