Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 80: 1258-1262, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barazanji, K. W.
Right arrow Articles by Hsia, C. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barazanji, K. W.
Right arrow Articles by Hsia, C. C.

Journal of Applied Physiology, Vol 80, Issue 4 1258-1262, Copyright © 1996 by American Physiological Society


ARTICLES

A modified rebreathing technique using an infrared gas analyzer

K. W. Barazanji, M. Ramanathan, R. L. Johnson Jr and C. C. Hsia
Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas 75235-9034, USA.

To lower the cost and improve accessibility of the rebreathing technique for measuring cardiopulmonary function during exercise, we implemented a fast-response infrared (IR) gas-analyzer system to simultaneously measure lung diffusing capacity, cardiac output lung tissue volume, and lung volume by a rebreathing technique in five healthy subjects at rest and during steady-state exercise. Interferences by water vapor and CO2 on the analyzer were determined and corrected for. During rebreathing, a gas mixture of 0.4% C2H2-0.3% CH4-9% He-30% O2, and either 0.3% C18O or 0.3% C16O in a balance of N2 was simultaneously sampled by both a mass spectrometer and the IR analyzer, permitting paired comparisons. Measurements obtained by the two devices were not significantly different. We conclude that this modified rebreathing technique using the IR analyzer is accurate for the measurement of cardiopulmonary function at rest and during exercise.


This article has been cited by other articles:


Home page
ChestHome page
C. Yilmaz, W. W. Chance, R. L. Johnson Jr, and C. C. W. Hsia
Simulation System for a Rebreathing Technique To Measure Multiple Cardiopulmonary Function Parameters
Chest, May 1, 2009; 135(5): 1309 - 1314.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. Yilmaz, D. M. Dane, and C. C. W. Hsia
Assessing recruitment of lung diffusing capacity in exercising guinea pigs with a rebreathing technique
J Appl Physiol, July 1, 2008; 105(1): 316 - 321.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. R. Phansalkar, C. M. Hanson, A. R. Shakir, R. L. Johnson Jr., and C. C. W. Hsia
Nitric Oxide Diffusing Capacity and Alveolar Microvascular Recruitment in Sarcoidosis
Am. J. Respir. Crit. Care Med., May 1, 2004; 169(9): 1034 - 1040.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. M. Tamhane, R. L. Johnson Jr., and C. C. W. Hsia
Pulmonary Membrane Diffusing Capacity and Capillary Blood Volume Measured During Exercise From Nitric Oxide Uptake
Chest, December 1, 2001; 120(6): 1850 - 1856.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online