Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 80: 1233-1239, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sato, K. T.
Right arrow Articles by Sato, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sato, K. T.
Right arrow Articles by Sato, K.

Journal of Applied Physiology, Vol 80, Issue 4 1233-1239, Copyright © 1996 by American Physiological Society


ARTICLES

Reexamination of tympanic membrane temperature as a core temperature

K. T. Sato, N. L. Kane, G. Soos, C. V. Gisolfi, N. Kondo and K. Sato
Marshall Dermatology Research Laboratories, Department of Dermatology, University of Iowa College of Medicine, Iowa City 52242, USA.

Controversies surrounding tympanic temperature (Tty) itself and techniques for measuring it have dampened the potential usefulness of Tty in determining core temperature (operationally defined here as the body temperature taken at a deep body site). The present study was designed to address the following questions. 1) Can a tympanic membrane probe be made that is safer and more reliable than its predecessors? 2) Why is the effect of facial cooling and heating on Tty so inconsistent in reports from different laboratories? 3) Is Tty still useful as a measure of core temperature? Data from this study, obtained with a modified thermocouple probe, suggest that the widely reported facial skin cooling effect on Tty is most probably due to thermal contamination from the surrounding ear canal wall and/or suboptimal contact of the probe sensor with the tympanic membrane because 1) Tty that fell during facial cooling was increased to the precooling level by the repositioning of the probe sensor; 2) Tty determined by using a probe with a larger sensor area (the sensor soldered to a steel wire ring)tended to fall in response to facial cooling, whereas Tty determined with a thermally insulated probe ring did not; and 3) Tty obtained under careful positioning of the insulated probe was relatively insensitive to facial cooling or heating. Because Tty was practically identical to esophageal temperature (Tes) in the steady state, i.e., 36.83 +/- 0.20 (SD) degrees C for Tty and 36.87 +/- 0.16 degrees C for Tes at room temperature (n = 11), and because facial cooling had little effect on both Tty and Tes (36.86 +/- 0.17 degrees C for Tty and 36.86 +/- 0.26 degrees C for Tes during facial or scalp skin cooling), we support the postulate that Tty is a good measure of core temperature. The temperature transient in response to foot warming was detected 5 min (n = 2) faster with Tty than with Tes. Thus, with further improvements in the design of the probe. Tty can become a standard for determination of core body temperature.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
E. B. Rein, M. Filtvedt, L. Walloe, and J. C. Raeder
Hypothermia during laparotomy can be prevented by locally applied warm water and pulsating negative pressure
Br. J. Anaesth., March 1, 2007; 98(3): 331 - 336.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Michikami, A. Kamiya, Q. Fu, S. Iwase, T. Mano, and K. Sunagawa
Attenuated thermoregulatory sweating and cutaneous vasodilation after 14-day bed rest in humans
J Appl Physiol, January 1, 2004; 96(1): 107 - 114.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. Mucci, F. Durand, B. Lebel, J. Bousquet, and C. Prefaut
Basophils and exercise-induced hypoxemia in extreme athletes
J Appl Physiol, March 1, 2001; 90(3): 989 - 996.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
Z. Mariak, M. D. White, J. Lewko, T. Lyson, and P. Piekarski
Direct cooling of the human brain by heat loss from the upper respiratory tract
J Appl Physiol, November 1, 1999; 87(5): 1609 - 1613.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Grahn, J. G. Brock-Utne, D. E. Watenpaugh, and H. C. Heller
Recovery from mild hypothermia can be accelerated by mechanically distending blood vessels in the hand
J Appl Physiol, November 1, 1998; 85(5): 1643 - 1648.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Shibasaki, N. Kondo, H. Tominaga, K. Aoki, E. Hasegawa, Y. Idota, and T. Moriwaki
Continuous measurement of tympanic temperature with a new infrared method using an optical fiber
J Appl Physiol, September 1, 1998; 85(3): 921 - 926.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online