Journal of Applied Physiology, Vol 80, Issue 4 1233-1239, Copyright © 1996 by American Physiological Society
ARTICLES |
K. T. Sato, N. L. Kane, G. Soos, C. V. Gisolfi, N. Kondo and K. Sato
Marshall Dermatology Research Laboratories, Department of Dermatology, University of Iowa College of Medicine, Iowa City 52242, USA.
Controversies surrounding tympanic temperature (Tty) itself and techniques for measuring it have dampened the potential usefulness of Tty in determining core temperature (operationally defined here as the body temperature taken at a deep body site). The present study was designed to address the following questions. 1) Can a tympanic membrane probe be made that is safer and more reliable than its predecessors? 2) Why is the effect of facial cooling and heating on Tty so inconsistent in reports from different laboratories? 3) Is Tty still useful as a measure of core temperature? Data from this study, obtained with a modified thermocouple probe, suggest that the widely reported facial skin cooling effect on Tty is most probably due to thermal contamination from the surrounding ear canal wall and/or suboptimal contact of the probe sensor with the tympanic membrane because 1) Tty that fell during facial cooling was increased to the precooling level by the repositioning of the probe sensor; 2) Tty determined by using a probe with a larger sensor area (the sensor soldered to a steel wire ring)tended to fall in response to facial cooling, whereas Tty determined with a thermally insulated probe ring did not; and 3) Tty obtained under careful positioning of the insulated probe was relatively insensitive to facial cooling or heating. Because Tty was practically identical to esophageal temperature (Tes) in the steady state, i.e., 36.83 +/- 0.20 (SD) degrees C for Tty and 36.87 +/- 0.16 degrees C for Tes at room temperature (n = 11), and because facial cooling had little effect on both Tty and Tes (36.86 +/- 0.17 degrees C for Tty and 36.86 +/- 0.26 degrees C for Tes during facial or scalp skin cooling), we support the postulate that Tty is a good measure of core temperature. The temperature transient in response to foot warming was detected 5 min (n = 2) faster with Tty than with Tes. Thus, with further improvements in the design of the probe. Tty can become a standard for determination of core body temperature.
This article has been cited by other articles:
![]() |
E. B. Rein, M. Filtvedt, L. Walloe, and J. C. Raeder Hypothermia during laparotomy can be prevented by locally applied warm water and pulsating negative pressure Br. J. Anaesth., March 1, 2007; 98(3): 331 - 336. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Michikami, A. Kamiya, Q. Fu, S. Iwase, T. Mano, and K. Sunagawa Attenuated thermoregulatory sweating and cutaneous vasodilation after 14-day bed rest in humans J Appl Physiol, January 1, 2004; 96(1): 107 - 114. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Mucci, F. Durand, B. Lebel, J. Bousquet, and C. Prefaut Basophils and exercise-induced hypoxemia in extreme athletes J Appl Physiol, March 1, 2001; 90(3): 989 - 996. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Mariak, M. D. White, J. Lewko, T. Lyson, and P. Piekarski Direct cooling of the human brain by heat loss from the upper respiratory tract J Appl Physiol, November 1, 1999; 87(5): 1609 - 1613. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Grahn, J. G. Brock-Utne, D. E. Watenpaugh, and H. C. Heller Recovery from mild hypothermia can be accelerated by mechanically distending blood vessels in the hand J Appl Physiol, November 1, 1998; 85(5): 1643 - 1648. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Shibasaki, N. Kondo, H. Tominaga, K. Aoki, E. Hasegawa, Y. Idota, and T. Moriwaki Continuous measurement of tympanic temperature with a new infrared method using an optical fiber J Appl Physiol, September 1, 1998; 85(3): 921 - 926. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |