Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 80: 559-563, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Woda, R. P.
Right arrow Articles by Lynn, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Woda, R. P.
Right arrow Articles by Lynn, L. A.

Journal of Applied Physiology, Vol 80, Issue 2 559-563, Copyright © 1996 by American Physiological Society


ARTICLES

Effect of measurement error on calculated variables of oxygen transport

R. P. Woda, R. D. Dzwonczyk, J. P. Orlowski, F. Van Lente and L. A. Lynn
Department of Anesthesiology, Ohio State University, Columbus 43210, USA.

The effect of measurement error in pH, PCO2, and PO2 on mathematically derived variables of oxygen transport in patients was delineated by comparing calculated oxygen saturations from a blood-gas machine with measured saturations from a CO-oximeter and further by modeling the error in a computer simulation. Twenty-one critically ill patients aged 30-84 yr were studied. A total of 80 arterial and 80 mixed venous blood gas samples were collected. The intraclass correlation results between measured and calculated arterial (SaO2) and mixed venous (Sv-O2) oxygen saturations were 0.59 and 0.68, respectively. The product-moment correlation for SaO2 was 0.75 and for Sv-O2 was 0.77. The percent error in calculating and measuring oxygen saturation was found to be greater at low PO2 values, whereas percent error of calculating oxygen consumption increased as the PO2 increased. Measurement repeatability at high PO2 is better than at low PO2 for both measured and calculated methods. We conclude from this comparison that measured and calculated SaO2 and Sv-O2 values are not interchangeable. Each can introduce substantial error in calculating oxygen consumption through error propagation and error amplification.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
T. S. Walsh
Recent advances in gas exchange measurement in intensive care patients
Br. J. Anaesth., July 1, 2003; 91(1): 120 - 131.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online