Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 80: 458-463, 1996;
8750-7587/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reybrouck, T.
Right arrow Articles by Gewillig, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reybrouck, T.
Right arrow Articles by Gewillig, M.

Journal of Applied Physiology, Vol 80, Issue 2 458-463, Copyright © 1996 by American Physiological Society


ARTICLES

Dynamics of respiratory gas exchange during exercise after correction of congenital heart disease

T. Reybrouck, L. Mertens, N. Kalis, M. Weymans, M. Dumoulin, W. Daenen and M. Gewillig
Department of Cardiorespiratory Rehabilitation, Gasthuisberg University Hospital, University of Leuven, Belgium.

In pediatric exercise testing, conventional measures of aerobic exercise function such as maximal O2 uptake or the ventilatory anaerobic threshold (VAT) use only one value for the assessment of exercise capacity. We studied a more comprehensive approach to evaluate aerobic exercise function by analyzing the steepness of the slope of CO2 production (VCO2) vs. VO2 above the VAT (S3). This was calculated in 32 patients operated on for congenital heart disease [16 for transposition of the great arteries (TGA) and 16 for tetralogy of Fallot (TF)] and was compared with 16 age-matched controls (nl). The results show that the reproducibility of this new assessment method was excellent (coefficient of variation for S3: 8.6%). S3 was significantly steeper (P<0.05) in the patients (1.31 +/- 0.22 for TGA and 1.28 +/- 0.16 for TF) compared with the nl (1.10 +/- 0.22). Also, the difference between S3 and the slope of VCO2 vs. VO2 below the VAT was significantly higher in the patients (0.37 +/- 0.22 for TGA and 0.31 +/- 0.10 for TF) than in controls (0.22 +/- 0.06). The steeper slopes were associated with lower than normal values for VAT and O2 during exercise. It is concluded that the analysis of the steepness of the slope of CO2 is a sensitive, reproducible, and objective approach to evaluate the integrative cardiopulmonary response to exercise. It complements the assessment of a subnormal VAT by reflecting the extent of anaerobic metabolism.


This article has been cited by other articles:


Home page
Eur Heart JHome page
T Reybrouck, B Eyskens, L Mertens, J Defoor, W Daenen, and M Gewillig
Cardiorespiratory exercise function after the arterial switch operation for transposition of the great arteries
Eur. Heart J., June 2, 2001; 22(12): 1052 - 1059.
[Abstract] [PDF]


Home page
ChestHome page
T. Reybrouck
Gas Exchange Kinetics in Patients With Cardiovascular Disease
Chest, August 1, 2000; 118(2): 285 - 286.
[Full Text] [PDF]


Home page
HeartHome page
T Reybrouck, L Mertens, S Brusselle, M Weymans, B Eyskens, J Defoor, and M Gewillig
Oxygen uptake versus exercise intensity: a new concept in assessing cardiovascular exercise function in patients with congenital heart disease
Heart, July 1, 2000; 84(1): 46 - 52.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Reybrouck and R. Fagard
Gender Differences in the Oxygen Transport System During Maximal Exercise in Hypertensive Subjects
Chest, March 1, 1999; 115(3): 788 - 792.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online