Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 79: 1512-1518, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gavriely, N.
Right arrow Articles by Grotberg, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gavriely, N.
Right arrow Articles by Grotberg, J. B.

Journal of Applied Physiology, Vol 79, Issue 5 1512-1518, Copyright © 1995 by American Physiological Society


ARTICLES

Comparative study of intra-airway gas transport by alternative modes of ventilation

N. Gavriely, D. P. Gaver 3rd, J. Solway and J. B. Grotberg
Department of Physiology and Biophysics, Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.

The effectiveness of three alternative modes of ventilation [high-frequency ventilation (HFV), constant-flow ventilation (CFV), and high-frequency external vibration ventilation (HFVV)] was compared. Local intra-airway gas transport was measured with catheters placed in the distal trachea and in bronchi located 5.5, 9, and 11 cm from the carina. A new bolus dispersion method was devised to measure the local effective diffusivities (Deff) induced by these modes of ventilation and by cardiogenic oscillations relative to molecular diffusivity (Dmol). Mixing induced by cardiogenic oscillations was 7 +/- 2- to 26 +/- 4-fold greater than by molecular diffusion alone. Intra-airway transport by CFV, applied at three flow rates (0.3, 1.0, and 3.0 l.min-1.kg-1), was most effective in the trachea but fell sharply in the more peripheral airways. Local transport by HFVV, at a frequency of 22 Hz and a vertical amplitude of 0.4 cm, was most effective in the periphery (Deff = 793 x Dmol), whereas the effectiveness of transport by HFV, applied with 10 and 20 ml at 22 Hz, was evenly distributed. Doubling the HFV oscillatory volume caused a 4.5 +/- 2.7-fold increase in Deff/Dmol. Combining HFVV with CFV at 0.3 l.min-1.kg-1 induced transport rates that were 187- to 2,034-fold greater than by molecular diffusion alone in the bronchi and a higher relative transport (due to convection) in the trachea. We conclude that the combination of HFVV with low-flow CFV provides a high rate of intra-airway transport with minimal mechanical perturbations to the pulmonary system.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. A. Adams, M. J. Mangino, J. Bassuk, D. M. Inman, and M. A. Sackner
Noninvasive motion ventilation (NIMV): a novel approach to ventilatory support
J Appl Physiol, December 1, 2000; 89(6): 2438 - 2446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online