Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 79: 1316-1319, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cha, K.
Right arrow Articles by Wilmore, D. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cha, K.
Right arrow Articles by Wilmore, D. W.

Journal of Applied Physiology, Vol 79, Issue 4 1316-1319, Copyright © 1995 by American Physiological Society


ARTICLES

Multifrequency bioelectrical impedance estimates the distribution of body water

K. Cha, G. M. Chertow, J. Gonzalez, J. M. Lazarus and D. W. Wilmore
Department of Surgery, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.

Multifrequency bioelectrical impedance analysis was used to estimate the ratio of extracellular water (ECW) to total body water in subjects with end-stage renal disease. The body's resistance was measured at frequencies ranging from 1 kHz to 1 MHz. The impedance index (height2/resistance) determined at low frequency (5 kHz) correlated most closely with ECW (r = 0.886) using sodium bromide dilution as the standard of comparison. In contrast, the ratio of height squared to resistance determined at high frequency (500 kHz) correlated most closely with total body water (r = 0.974) using deuterium oxide dilution as the standard of comparison. The ratio of resistance at 500 kHz to resistance at 5 kHz was directly correlated (r = 0.767) with the ratio of ECW to total body water. Multifrequency bioelectrical impedance analysis may assist in the evaluation of body water distribution in endstage renal disease and other clinical disorders of fluid volume and/or distribution.


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
P. Kotanko, N. W. Levin, and F. Zhu
Current state of bioimpedance technologies in dialysis
Nephrol. Dial. Transplant., March 1, 2008; 23(3): 808 - 812.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
S. W. Lee, J. H. Song, G. A Kim, K. J. Lee, and M.-J. Kim
Assessment of total body water from anthropometry-based equations using bioelectrical impedance as reference in Korean adult control and haemodialysis subjects
Nephrol. Dial. Transplant., January 1, 2001; 16(1): 91 - 97.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
Y. Toda, N. Segal, T. Toda, T. Morimoto, and R. Ogawa
Lean Body Mass and Body Fat Distribution in Participants With Chronic Low Back Pain
Arch Intern Med, November 27, 2000; 160(21): 3265 - 3269.
[Abstract] [Full Text] [PDF]


Home page
Ann. N. Y. Acad. Sci.Home page
P. KLASSEN, M. MAZARIEGOS, P. DEURENBERG, N. W. SOLOMONS, and P. FURST
Hydrational Status Assessed by Bioelectrical Impedance Spectroscopy and Dilution Methods in Patients with Classical Dengue Fever
Ann. N.Y. Acad. Sci., May 1, 2000; 904(1): 163 - 170.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
F. Zhu, D. Schneditz, E. Wang, and N. W. Levin
Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis
J Appl Physiol, August 1, 1998; 85(2): 497 - 504.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online