Journal of Applied Physiology AJP: Renal Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 79: 771-780, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peslin, R.
Right arrow Articles by Marchand, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peslin, R.
Right arrow Articles by Marchand, M.

Journal of Applied Physiology, Vol 79, Issue 3 771-780, Copyright © 1995 by American Physiological Society


ARTICLES

Analysis of low-frequency lung impedance in rabbits with nonlinear models

R. Peslin, C. Saunier, C. Duvivier and M. Marchand
Unite 14 de Physiopathologie Respiratoire, Institut National de la Sante et de la Recherche Medicale, Universite Henri Poincare Nancy I, Vandoeuvre-les-Nancy, France.

Lung mechanics was studied in six paralyzed tracheotomized rabbits ventilated with a specially devised computer-controlled ventilator. The target flow waveform contained noninteger multiple frequencies ranging from 0.83 to 6-10 Hz and met a neither-sum-nor-difference criterion to minimize the effects of nonlinearity (B. Suki and K. Lutchen. IEEE Trans. Biomed. Eng. 39: 1142-1151, 1992). The actual flow, however, contained harmonics of the two lowest frequencies. Measurements were performed at mean airway pressure (Paw) levels of 8 and 12 hPa and during histamine-induced bronchoconstriction. Smooth impedance curves were observed in unchallenged rabbits at low mean Paw levels. In contrast, unrealistic impedance fluctuations, suggestive of cross talk from the unwanted frequency components in the flow input, were seen at high mean Paw levels and during acute bronchoconstriction. Model analysis was performed by using the actual flow signal as an input to various nonlinear models. The impedance fluctuations observed at high mean Paw levels were well simulated by a model featuring a volume-dependent elastance, and those observed after histamine were almost perfectly reproduced by a model where resistance increased with the reciprocal of lung volume. We conclude that impedance data biased by cross talk may provide useful information on the presence and nature of respiratory system nonlinearities.


This article has been cited by other articles:


Home page
Eur Respir JHome page
K. Muramatsu, K. Yukitake, M. Nakamura, I. Matsumoto, and Y. Motohiro
Monitoring of nonlinear respiratory elastance using a multiple linear regression analysis
Eur. Respir. J., June 1, 2001; 17(6): 1158 - 1166.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Suki, H. Yuan, Q. Zhang, and K. R. Lutchen
Partitioning of lung tissue response and inhomogeneous airway constriction at the airway opening
J Appl Physiol, April 1, 1997; 82(4): 1349 - 1359.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online