Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 79: 243-250, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gavriely, N.
Right arrow Articles by Grotberg, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gavriely, N.
Right arrow Articles by Grotberg, J. B.

Journal of Applied Physiology, Vol 79, Issue 1 243-250, Copyright © 1995 by American Physiological Society


ARTICLES

Intra-airway gas transport during high-frequency chest vibration with tracheal insufflation in dogs

N. Gavriely, D. M. Eckmann and J. B. Grotberg
Department of Anesthesia, Northwestern University Medical School, Chicago 60611, USA.

High-frequency external chest vibration with tracheal insufflation (high-frequency vibration ventilation) has previously been shown to be an effective mode of artificial ventilation in experimental animals. To investigate the intra-airway gas mixing during high-frequency vibration ventilation (frequency 30 Hz, amplitude 0.4 cm), we used an analysis of the single-breath washout curve that gives the vibration-induced mixing coefficient distribution relative to the no-vibration situation. Data from four anesthetized dogs were collected during constant-flow insufflation at six rates (0.05-0.4 l.min-1.kg-1), at three insufflation durations (2, 4, and 7 s), and with the insufflation catheter outlet at three positions (carina, trachea, and a bronchus) while the vibration was on and off. Vibration enhanced intra-airway gas mixing 14.1 +/- 3.9-fold, with the peak of the enhancement distribution located 125 +/- 29 ml from the airway opening and a distribution width of 121 +/- 29 ml. As insufflation flow increased, the position of the peak enhancement shifted toward the alveolar zone and diminished in peak amplitude. Changing the insufflation duration and the catheter position did not affect the intra-airway mixing induced by vibration. External chest vibration causes a substantial increase of intra-airway gas mixing, bringing alveolar gas to central airways. This leads to overall increased pulmonary gas transport when fresh gas is insufflating the tracheal carina area.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online