Journal of Applied Physiology Journal of Neurophysiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 78: 2153-2160, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rotger, M.
Right arrow Articles by Farre, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rotger, M.
Right arrow Articles by Farre, R.

Journal of Applied Physiology, Vol 78, Issue 6 2153-2160, Copyright © 1995 by American Physiological Society


ARTICLES

Lung and respiratory impedance at low frequency during mechanical ventilation in rabbits

M. Rotger, R. Peslin, D. Navajas and R. Farre
Laboratorio de Biofisica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Spain.

We have tested in eight rabbits the feasibility of measuring respiratory (Zrs) and lung (ZL) impedances in the low-frequency domain, including below the breathing frequency (fb), during conventional mechanical ventilation (CMV). The animals were tracheotomized and ventilated with a tidal volume (VT) of 20 ml at a fb of 1 Hz. The excitation signal was provided by a flow generator connected in parallel with the ventilator; it included six components ranging from 0.45 to 14.8 Hz, which met the neither-sum-nor-difference criterion of B. Suki and K. Lutchen (IEEE Trans. Biomed. Eng. 39: 1142-1151, 1992) to minimize the influence of nonlinearities. Zrs and ZL were also measured at the same mean lung volume and with the same excitation signal both during apnea and when the ventilator signal was replaced by a sine wave with the same VT and fb (SMV). The real parts (Re) of both Zrs and ZL, as well as the effective elastances, were significantly larger during apnea than during CMV and SMV over the whole frequency range. Re(Zrs) and Re(ZL) were similar during CMV and SMV above fb but they were lower during CMV at 0.45 Hz. The latter difference seems to be related to the presence of harmonics of fb and of additional frequency components due to pulse amplitude modulation. We conclude that, because of nonlinearities, it is feasible to measure Zrs and ZL during CMV only at and above fb.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. F. M. Gomes, X. Shen, R. Ramchandani, R. S. Tepper, and J. H. T. Bates
Comparative respiratory system mechanics in rodents
J Appl Physiol, September 1, 2000; 89(3): 908 - 916.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Suki, H. Yuan, Q. Zhang, and K. R. Lutchen
Partitioning of lung tissue response and inhomogeneous airway constriction at the airway opening
J Appl Physiol, April 1, 1997; 82(4): 1349 - 1359.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online