Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 78: 663-669, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simon, B. A.
Right arrow Articles by Venegas, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simon, B. A.
Right arrow Articles by Venegas, J. G.

Journal of Applied Physiology, Vol 78, Issue 2 663-669, Copyright © 1995 by American Physiological Society


ARTICLES

Ventilation distribution and regional lung impedance during partial unilateral bronchial obstruction

B. A. Simon, K. Tsuzaki and J. G. Venegas
Department of Anesthesia, Massachusetts General Hospital, Harvard Medical School, Boston 02114, USA.

Significant degrees of main-stem bronchial obstruction may not have a detectable effect on ventilation distribution at normal breathing frequencies. We determined the effect of graded left main-stem bronchial obstruction (area reduction of 50 and 70%) on the distribution of tidal volume (VT) and mean lung volume (VL) using radioactive 13NN and two-dimensional planar positron imaging in six supine anesthetized tracheotomized dogs. Measurements were made during eucapnic high-frequency oscillatory ventilation at frequencies (f) of 0.2, 1, 5, and 10 Hz. Right and left lung respiratory system complex impedance (Z) values were assessed by simultaneous measurements of dynamic regional lung volume by positron imaging and carinal pressure. The results show a progressive shift of VT away from the obstruction at f > 1 Hz, with VT left-to-right (L/R) ratios of 0.9, 0.9, 0.58, and 0.46 at f of 0.2, 1, 5, and 10 Hz, respectively, for 70% obstruction. VT shifts with f for 50% obstruction were similar but of lesser magnitude. VL L/R ratio was 0.88 and did not change with f or obstruction. The real part of Z was frequency dependent and increased at low f independent of obstruction. The real part of Z L/R ratio increased with obstruction at 5 and 10 Hz. At low f there was a difference between left and right imaginary parts of Z due to the difference in VL. There was no significant change in the imaginary part of Z as a result of obstruction. We conclude that up to a 70% unilateral bronchial obstruction is not detectable by distribution of ventilation at f < or = 1 Hz.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
B. A. Simon, K. Tsuzaki, and J. G. Venegas
Changes in regional lung mechanics and ventilation distribution after unilateral pulmonary artery occlusion
J Appl Physiol, March 1, 1997; 82(3): 882 - 891.