Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 78: 388-393, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fisher, J. A.
Right arrow Articles by Sommer, L. Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fisher, J. A.
Right arrow Articles by Sommer, L. Z.

Journal of Applied Physiology, Vol 78, Issue 2 388-393, Copyright © 1995 by American Physiological Society


ARTICLES

Dynamic measurement of tracheal diameter in dogs

J. A. Fisher, G. Volgyesi, D. D. Sommer, J. A. Silverman, A. K. Fink, A. A. Robicsek and L. Z. Sommer
Department of Anaesthesia, Mount Sinai Hospital, Toronto, Ontario, Canada.

We describe and validate a new minimally invasive method for continuous measurement of tracheal diameter in anesthetized dogs. The method is based on measuring displacement of water into and out of a modified endotracheal tube cuff placed in the trachea. The system was calibrated to allow tracheal diameter to be calculated from known cuff volume. The resolution of the method in measuring changes in tracheal diameter is 0.1 mm over a range of approximately 10-25 mm. The apparatus was tested in five dogs by observing the response of the trachea to four stimuli previously shown to alter tracheal tone: stimulation of nasal mucosa, hyperinflation of the lungs, induction of hypocapnea, and infusion of atropine. The observed changes in tracheal diameter were generally consistent with those of previous studies. The direction and extent of changes in tracheal diameter in response to the test conditions were confirmed by fluoroscopy. We conclude that continuous measurement of volume changes in the cuff reflects corresponding changes in tracheal diameter.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. A. Silverman, L. Z. Sommer, A. Robicsek, J. Dickstein, A. Greenberg, J. Kruger, J. Rucker, G. Volgyesi, J. A. Fisher, and S. Iscoe
Tracheal constrictor drive above the apneic threshold in anesthetized dogs
J Appl Physiol, December 1, 2000; 89(6): 2258 - 2262.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Kondo, I. Kobayashi, N. Hayama, G. Tazaki, and Y. Ohta
Respiratory-related bronchial rhythmic constrictions in the dog with extracorporeal circulation
J Appl Physiol, June 1, 2000; 88(6): 2031 - 2036.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online