Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 78: 359-367, 1995;
8750-7587/95 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beadle, R. E.
Right arrow Articles by Kou, A. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beadle, R. E.
Right arrow Articles by Kou, A. H.

Journal of Applied Physiology, Vol 78, Issue 1 359-367, Copyright © 1995 by American Physiological Society


ARTICLES

Characterization of a density-corrected ultrasonic pneumotachometer for horses

R. E. Beadle, A. J. Guthrie and A. H. Kou
Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge 70803.

A density-corrected ultrasonic pneumotachometer designed specifically for horses (UF202) was evaluated and characterized with the aid of a custom-built apparatus. UF202 provided voltage outputs for airflow through and gas density within the flowhead. Baseline stability for flow channel output (VUF202) was < 0.35% full scale (FS), and VUF202 was linear over a range of +/- 50 l/s (R2 > or = 0.9976). Under optimal conditions, VUF202 accuracy was determined to be +/- 1.00% FS and repeatability was +/- 0.78% FS. VUF202 resolution was 24 ml/s. The rise time for VUF202 was 18 ms, and the -3-dB point was 18 Hz; digital compensation provided a flat frequency response to 32 Hz. VUF202 gain appeared to be stable over a period of 8 days. Density channel output (PUF202) was linear over a range of 1.11-1.23 g/l (R2 > or = 0.9645). PUF202 accuracy was calculated to be +/- 0.50% FS, and PUF202 repeatability was determined to be +/- 0.30% FS. Resistance of the flowhead was determined to be 0.013 cmH2O.l-1.s at a flow of 40 l/s. On the basis of this study, we conclude that UF202 should facilitate accurate measurement of breath-by-breath airflow of exercising horses.