Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 77: 2659-2665, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Porszasz, J.
Right arrow Articles by Wasserman, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Porszasz, J.
Right arrow Articles by Wasserman, K.

Journal of Applied Physiology, Vol 77, Issue 6 2659-2665, Copyright © 1994 by American Physiological Society


ARTICLES

Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise

J. Porszasz, T. J. Barstow and K. Wasserman
Department of Medicine, University of California, Los Angeles Harbor Medical Center, Torrance 90509.

We evaluated the effect of airflow and gas composition on the linearity of measurement of airflow by a new disposable flowmeter. The flowmeter is based on the principle of differential pressure measurement across two symmetrically disposed Pitot tubes. Nonlinearities arising from the pressure-to-airflow relationship and sensitivity to changes in gas density were linearized with appropriate software and monitoring of the gas composition. With room air used as the respired gas, the measured tidal volume from a piston pump assembly was consistently within 1-2% of the target tidal volume for each of five flowmeters tested across physiological ranges of flow. Changing gas densities by varying concentrations of O2, CO2, and N2 led to errors in tidal volume measurement that ranged up to 6-8%. However, because the errors were predictable, they were corrected by software to within 0.6% of the target volume. Measurement of minute ventilation during exercise was within 1-2% of that determined from bag collections. We conclude that this type of flowmeter can accurately measure exercise minute ventilation and has advantages over some other flowmeters because of its ruggedness, reproducibility, and ease of sterilization or replacement compared with other flowmeters.


This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
F. M. Iaia, M. Thomassen, H. Kolding, T. Gunnarsson, J. Wendell, T. Rostgaard, N. Nordsborg, P. Krustrup, L. Nybo, Y. Hellsten, et al.
Reduced volume but increased training intensity elevates muscle Na+-K+ pump {alpha}1-subunit and NHE1 expression as well as short-term work capacity in humans
Am J Physiol Regulatory Integrative Comp Physiol, March 1, 2008; 294(3): R966 - R974.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
M. Mohr, P. Krustrup, J. J. Nielsen, L. Nybo, M. K. Rasmussen, C. Juel, and J. Bangsbo
Effect of two different intense training regimens on skeletal muscle ion transport proteins and fatigue development
Am J Physiol Regulatory Integrative Comp Physiol, April 1, 2007; 292(4): R1594 - R1602.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. G. Williams, S. S. Dhamrait, P. T. E. Wootton, S. H. Day, E. Hawe, J. R. Payne, S. G. Myerson, M. World, R. Budgett, S. E. Humphries, et al.
Bradykinin receptor gene variant and human physical performance
J Appl Physiol, March 1, 2004; 96(3): 938 - 942.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ACCP Statement on Cardiopulmonary Exercise Testing
Am. J. Respir. Crit. Care Med., January 15, 2003; 167(2): 211 - 277.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. R. Bassett Jr., E. T. Howley, D. L. Thompson, G. A. King, S. J. Strath, J. E. McLaughlin, and B. B. Parr
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
J Appl Physiol, July 1, 2001; 91(1): 218 - 224.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. E. F. Pedersen, P. Robach, J.-P. Richalet, and P. A. Robbins
Peripheral chemoreflex function in hyperoxia following ventilatory acclimatization to altitude
J Appl Physiol, July 1, 2000; 89(1): 291 - 296.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Jones, P M Elliott, S Sharma, W J McKenna, and B J Whipp
Cardiopulmonary responses to exercise in patients with hypertrophic cardiomyopathy
Heart, July 1, 1998; 80(1): 60 - 67.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
P. Robach, D. Biou, J.-P. Herry, D. Deberne, M. Letournel, J. Vaysse, and J.-P. Richalet
Recovery processes after repeated supramaximal exercise at the altitude of 4,350 m
J Appl Physiol, June 1, 1997; 82(6): 1897 - 1904.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online