Journal of Applied Physiology AJP: Renal Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 77: 1294-1302, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ying, X.
Right arrow Articles by Bhattacharya, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ying, X.
Right arrow Articles by Bhattacharya, J.

Journal of Applied Physiology, Vol 77, Issue 3 1294-1302, Copyright © 1994 by American Physiological Society


ARTICLES

Removal of albumin microinjected in rat lung perimicrovascular space

X. Ying, R. Qiao, S. Ishikawa and J. Bhattacharya
St. Luke's-Roosevelt Hospital Center, Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, New York 10019.

We used a microinjection approach to assess hydraulic properties of lung perimicrovascular adventitia (interstitial cuff surrounding microvessels). Isolated blood-perfused rat lungs held at constant airway pressure were microscopically viewed to identify subpleural venules (20 microns diam). Venular adventitia were microinjected with 20 nl of fluorescent albumin (4 g/dl), and then adventitial fluorescence was quantified at the injection site by either photometery or imaging. Nonlinear decay of adventitial fluorescence indicated liquid flux from the injection site into normal interstitium. In some experiments, we determined that the adventitial fluorescence flowed longitudinally along the venule length and filled single lymphatics. The fluorescence decay at the injection site was best described by equations of convective but not diffusive transport. The decay time constant (time to 37% initial), which relates inversely to hydraulic conductivity, increased 10-fold above baseline on lung expansion with airway pressure from 5 to 15 cmH2O (P < 0.05). However, presence or absence of blood flow, increase in filtration pressure, and tissue edema were all without effect on the time constant. Our estimate of the lower limit of baseline adventitial hydraulic conductivity was 5 x 10(-6) ml.cm-2.s-1.cmH2O-1. We conclude that hydraulic conductivity of perimicrovascular adventitia is not augmented by edema but that it is decreased by lung expansion.


This article has been cited by other articles:


Home page
Circ. Res.Home page
X. Ying, Y. Minamiya, C. Fu, and J. Bhattacharya
Ca2+ Waves in Lung Capillary Endothelium
Circ. Res., October 1, 1996; 79(4): 898 - 908.