Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 77: 84-92, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yue, G.
Right arrow Articles by Enoka, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yue, G.
Right arrow Articles by Enoka, R. M.

Journal of Applied Physiology, Vol 77, Issue 1 84-92, Copyright © 1994 by American Physiological Society


ARTICLES

Sensitivity of muscle proton spin-spin relaxation time as an index of muscle activation

G. Yue, A. L. Alexander, D. H. Laidlaw, A. F. Gmitro, E. C. Unger and R. M. Enoka
Department of Physiology, University of Arizona, Tucson 85721.

The purpose of this study was to determine the minimum number of contractions that are needed to detect an increase in the muscle proton spin-spin relaxation time (T2) at a given exercise intensity. Five healthy human subjects performed five sets of an exercise that included concentric and eccentric contractions of the elbow-flexor muscles with loads that were 25 or 80% of maximum. With the 80% load, the five sets involved 1, 2, 5, 10, or 20 repetitions of the exercise; with the 25% load the five sets were 2, 5, 10, 20, or 40 repetitions. The upper arm of each subject was imaged before and immediately after each set of the exercise. Spin-echo images (repetition time/echo time = 2,000 ms/30, 60, 90, and 120 ms) were collected using an extremity coil, and T2 values were calculated. The signal intensity was measured from the elbow-flexor and -extensor muscles and from the bone marrow of the humerus. With the 80% load, T2 increased in the short head of the biceps brachii after two repetitions of the elbow exercise and after five repetitions in the brachialis and the long head of the biceps brachii. With the 25% load, T2 became longer after five repetitions of the exercise for the short head of the biceps brachii and after 10 repetitions for the brachialis and the long head of the biceps brachii. T2 varied linearly with the number of contraction repetitions for each of the elbow-flexor muscles at either load (r2 > or = 0.97, P < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
ptjournalHome page
R. L Segal
Use of Imaging to Assess Normal and Adaptive Muscle Function
Physical Therapy, June 1, 2007; 87(6): 704 - 718.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
Y. Takeda, S. Kashiwaguchi, T. Matsuura, T. Higashida, and A. Minato
Hamstring Muscle Function After Tendon Harvest for Anterior Cruciate Ligament Reconstruction: Evaluation With T2 Relaxation Time of Magnetic Resonance Imaging
Am. J. Sports Med., February 1, 2006; 34(2): 281 - 288.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
Y. Takeda, S. Kashiwaguchi, K. Endo, T. Matsuura, and T. Sasa
The Most Effective Exercise for Strengthening the Supraspinatus Muscle : Evaluation by Magnetic Resonance Imaging
Am. J. Sports Med., May 1, 2002; 30(3): 374 - 381.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
D. W. Russ, M. A. Elliott, K. Vandenborne, G. A. Walter, and S. A. Binder-Macleod
Metabolic costs of isometric force generation and maintenance of human skeletal muscle
Am J Physiol Endocrinol Metab, February 1, 2002; 282(2): E448 - E457.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. P. Pappas, E. W. Olcott, and J. E. Drace
Imaging of skeletal muscle function using 18FDG PET: force production, activation, and metabolism
J Appl Physiol, January 1, 2001; 90(1): 329 - 337.
[Abstract] [Full Text] [PDF]


Home page
Journals of Gerontology Series A: Biological Sciences and Medical SciencesHome page
L. L. Ploutz-Snyder, E. L. Yackel-Giamis, A. E. Rosenbaum, and M. Formikell
Use of Muscle Functional Magnetic Resonance Imaging With Older Individuals
J. Gerontol. A Biol. Sci. Med. Sci., October 1, 2000; 55(10): 504B - 511.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
G. Saab, R. T. Thompson, and G. D. Marsh
Effects of exercise on muscle transverse relaxation determined by MR imaging and in vivo relaxometry
J Appl Physiol, January 1, 2000; 88(1): 226 - 233.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. A. Sloniger, K. J. Cureton, B. M. Prior, and E. M. Evans
Lower extremity muscle activation during horizontal and uphill running
J Appl Physiol, December 1, 1997; 83(6): 2073 - 2079.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. S. Conley, M. H. Stone, M. Nimmons, and G. A. Dudley
Resistance training and human cervical muscle recruitment plasticity
J Appl Physiol, December 1, 1997; 83(6): 2105 - 2111.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. A. Hardy and G. Yue
Measurement of magnetic resonance T2 for physiological experiments
J Appl Physiol, September 1, 1997; 83(3): 904 - 911.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. A. Sloniger, K. J. Cureton, B. M. Prior, and E. M. Evans
Anaerobic capacity and muscle activation during horizontal and uphill running
J Appl Physiol, July 1, 1997; 83(1): 262 - 269.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online