Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 2497-2509, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsuda, A.
Right arrow Articles by Fredberg, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsuda, A.
Right arrow Articles by Fredberg, J. J.

Journal of Applied Physiology, Vol 76, Issue 6 2497-2509, Copyright © 1994 by American Physiological Society


ARTICLES

Effects of alveolated duct structure on aerosol kinetics. I. Diffusional deposition in the absence of gravity

A. Tsuda, J. P. Butler and J. J. Fredberg
Department of Environmental Health, Harvard School of Public Health, Boston, Massachusetts 02115.

We examined the effects of alveolar duct structure on particle deposition in the pulmonary acinus. The low Reynolds number velocity field of carrier gas in a geometric model of the alveolated duct was solved numerically. Particle trajectories were computed from the Langevin equation. Conditional probabilities of the trajectories were calculated with an eigenfunction expansion technique in the absence of gravity. For submicron particles, Brownian motion dominated the process; the deposition rate dramatically decreased with boundary layer growth. For fine particles, fully developed boundary layer profiles determined the deposition over most of the acinar length. The assumption of a uniform radial profile results in a substantial overestimation of the local deposition rate. The deposition rate in an alveolated duct was always smaller than that in an equivalent straight tube of the same volume. Within the alveolus the deposition pattern was markedly nonuniform, with higher deposition near the alveolar entrance ring; this finding is consistent with experimental observations in animals (e.g., see Zeltner et al. J. Appl. Physiol. 70: 1137-1145, 1991). We conclude that the structure of the alveolar duct has an important influence on aerosol particle deposition in the lung acinus.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
I. Galvin, G. B. Drummond, and M. Nirmalan
Distribution of blood flow and ventilation in the lung: gravity is not the only factor
Br. J. Anaesth., April 1, 2007; 98(4): 420 - 428.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Haber, D. Yitzhak, and A. Tsuda
Gravitational deposition in a rhythmically expanding and contracting alveolus
J Appl Physiol, August 1, 2003; 95(2): 657 - 671.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. W. Glenny, S. L. Bernard, and H. T. Robertson
Pulmonary blood flow remains fractal down to the level of gas exchange
J Appl Physiol, August 1, 2000; 89(2): 742 - 748.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. Darquenne, M. Paiva, J. B. West, and G. K. Prisk
Effect of microgravity and hypergravity on deposition of 0.5- to 3-µm-diameter aerosol in the human lung
J Appl Physiol, December 1, 1997; 83(6): 2029 - 2036.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online