Journal of Applied Physiology Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 2428-2436, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cauberghs, M.
Right arrow Articles by Van de Woestijne, K. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cauberghs, M.
Right arrow Articles by Van de Woestijne, K. P.

Journal of Applied Physiology, Vol 76, Issue 6 2428-2436, Copyright © 1994 by American Physiological Society


ARTICLES

Shunt properties of large intrathoracic airways

M. Cauberghs, E. Verbeken and K. P. Van de Woestijne
Labortorium voor Pneumologie, Universitair Ziekenhuis Gasthuisberg, Leuven, Belgium.

The impedance of the wall of human intrathoracic trachea and central airways was measured by submitting preparations of excised airways to forced oscillations at various frequencies from 2 to 32 Hz. Both real (resistance) and imaginary (reactance) parts of wall impedance demonstrate a marked frequency dependence, varying with transmural pressure. These variations of resistance and reactance are related and are linked to the static elastic properties of the airways. The data allow us to calculate the total shunt impedance of the central intrathoracic airways. When the latter shunt values are used to correct measurements of impedance values of excised emphysematous lungs, it turns out that the shunt does not modify markedly the observed frequency dependence of resistance and compliance of those lungs, at least at transpulmonary pressures > 0.2 kPa. A model study suggests, in addition, that the latter frequency characteristics cannot be explained satisfactorily by parallel mechanical inhomogeneities. We submit that the frequency dependence of resistance and compliance of excised emphysematous lungs is determined mainly by the visco- and/or plastoelastic properties of lung tissue itself.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online