Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 2348-2355, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lieber, B. B.
Right arrow Articles by Grant, B. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lieber, B. B.
Right arrow Articles by Grant, B. J.

Journal of Applied Physiology, Vol 76, Issue 6 2348-2355, Copyright © 1994 by American Physiological Society


ARTICLES

Beat-by-beat changes of viscoelastic and inertial properties of the pulmonary arteries

B. B. Lieber, Z. Li and B. J. Grant
Department of Mechanical and Aerospace Engineering, State University of New York at Buffalo 14260.

We tested the hypothesis that pulmonary arterial input impedance varies during the ventilatory cycle due to alterations not only of the viscoelastic components of the pulmonary vasculature but also due to changes of the inertial components. A four-element lumped-parameter model was used to fit the pulmonary arterial pressure-flow recordings in the time domain in 10 anesthetized dogs. The four elements consisted of a resistor (R) that represents input resistance, a second resistor (R1) and a capacitor (C1) that represent the viscoelastic properties of the pulmonary vasculature, and an inductor (L1) that represents inertial properties of blood within the pulmonary vasculature. The parameters were evaluated at each heartbeat throughout the ventilatory cycle at three levels of positive end-expiratory pressure. All four parameters varied significantly during the ventilatory cycle. R, C1, L1, and R1 varied by up to 97, 33, 13, and 17%, respectively. Changes in parameter values were most apparent at the start of expiration when the most rapid changes of lung volume occur. This pattern of the results is consistent with the hypothesis that the time variation of pulmonary arterial impedance is due to dynamic shifts of blood volume between the extra-alveolar and alveolar arteries.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. H. Hollander, J.-J. Wang, G. M. Dobson, K. H. Parker, and J. V. Tyberg
Negative wave reflections in pulmonary arteries
Am J Physiol Heart Circ Physiol, August 1, 2001; 281(2): H895 - H902.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
P. M. Heerdt and M. L. Dickstein
Assessment of Right Ventricular Function
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 1997; 1(3): 215 - 224.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online