Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 1560-1565, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nielsen, O. W.
Right arrow Articles by Gronlund, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nielsen, O. W.
Right arrow Articles by Gronlund, J.

Journal of Applied Physiology, Vol 76, Issue 4 1560-1565, Copyright © 1994 by American Physiological Society


ARTICLES

Precision and accuracy of a noninvasive inert gas washin method for determination of cardiac output in men

O. W. Nielsen, S. Hansen and J. Gronlund
Department of Physiology, University of Odense, Denmark.

Stout et al. (J. Appl. Physiol. 38:913-918, 1975) suggested an open-circuit multibreath (MB) inert gas method for determining pulmonary capillary blood flow (Qc) in anesthetized dogs receiving artificial ventilation. In the present work we investigated the accuracy and reproducibility of the MB method in nine healthy human subjects at spontaneous ventilation, and we compared the MB method with the inert gas rebreathing (RB) method. Qc was calculated at rest and during exercise at 50 or 100 W, and experimental errors were evaluated in computer simulations of a two-alveoli lung model. The calculated mean Qc values of the MB method were 5.56 +/- 1.23 (SD), 10.02 +/- 0.78, and 13.2 +/- 0.84 l/min, and the mean difference (MB Qc - RB Qc) was not significantly different (P > 0.05). The variation in Qc of the MB method was found to be significantly larger than that in Qc of the RB method (P < 0.01). Random measurement errors and uneven distribution of ventilation contributed to the experimental errors. We conclude that the MB method is inferior to the RB method but that the MB method may be useful under exercise conditions.


This article has been cited by other articles:


Home page
Eur Respir JHome page
A. Vonk-Noordegraaf, S. A. van Wolferen, J. T. Marcus, A. Boonstra, P. E. Postmus, J. W. L. Peeters, and A. J. Peacock
Noninvasive assessment and monitoring of the pulmonary circulation
Eur. Respir. J., April 1, 2005; 25(4): 758 - 766.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. D. Johnson, K. C. Beck, D. N. Proctor, J. Miller, N. M. Dietz, and M. J. Joyner
Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick
J Appl Physiol, May 1, 2000; 88(5): 1650 - 1658.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. M. HOEPER, R. MAIER, J. TONGERS, J. NIEDERMEYER, J. M. HOHLFELD, M. HAMM, and H. FABEL
Determination of Cardiac Output by the Fick Method, Thermodilution, and Acetylene Rebreathing in Pulmonary Hypertension
Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 535 - 541.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
J. S. Clark, Y. J. Lin, M. J. Criddle, A. G. Cutillo, A. H. Bigler, F. L. Farr, and A. D. Renzetti Jr.
Cardiac output and mixed venous oxygen content measurements by a tracer bolus method: theory
J Appl Physiol, September 1, 1997; 83(3): 884 - 896.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online