Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 1494-1501, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Soparkar, G. R.
Right arrow Articles by Cotton, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Soparkar, G. R.
Right arrow Articles by Cotton, D. J.

Journal of Applied Physiology, Vol 76, Issue 4 1494-1501, Copyright © 1994 by American Physiological Society


ARTICLES

Measurement of temporal changes in DLSBCO-3EQ from small alveolar samples in normal subjects

G. R. Soparkar, J. T. Mink, B. L. Graham and D. J. Cotton
Department of Medicine, University of Saskatchewan, Saskatoon, Canada.

The dynamic changes in CO concentration [CO] during a single breath could be influenced by topographic inhomogeneity in the lung or by peripheral inhomogeneity due to a gas mixing resistance in the gas phase of the lung or to serial gradients in gas diffusion. Ten healthy subjects performed single-breath maneuvers by slowly inhaling test gas from functional residual capacity to one-half inspiratory capacity and slowly exhaling to residual volume with target breath-hold times of 0, 1.5, 3, 6, and 9 s. We calculated the three-equation single-breath diffusing capacity of the lung for CO (DLSBCO-3EQ) from the mean [CO] in both the entire alveolar gas sample and in four successive equal alveolar gas samples. DLSBCO-3EQ from the entire alveolar gas sample was independent of breath-hold time. However, with 0 s of breath holding, from early alveolar gas samples DLSBCO-3EQ was reduced and from late alveolar gas samples it was increased. With increasing breath-hold time, DLSBCO-3EQ from the earliest alveolar gas sample rapidly increased, whereas from the last alveolar gas sample it rapidly decreased such that all values from the small alveolar gas samples approached DLSBCO-3EQ from the entire alveolar sample. These changes correlated with ventilation inhomogeneity, as measured by the phase III He concentration slope and the mixing efficiency, and were larger for maneuvers with inspired volumes to one-half inspiratory capacity vs. total lung capacity.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
ChestHome page
M. J. M. Horstman, F. W. Mertens, D. Schotborg, H. C. Hoogsteden, and H. Stam
Comparison of Total-Breath and Single-Breath Diffusing Capacity in Healthy Volunteers and COPD Patients
Chest, January 1, 2007; 131(1): 237 - 244.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. C. W. Hsia, X. Yan, D. M. Dane, and R. L. Johnson Jr.
Density-dependent reduction of nitric oxide diffusing capacity after pneumonectomy
J Appl Physiol, May 1, 2003; 94(5): 1926 - 1932.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
B. L. Graham, J. T. Mink, and D. J. Cotton
Effects of Increasing Carboxyhemoglobin on the Single Breath Carbon Monoxide Diffusing Capacity
Am. J. Respir. Crit. Care Med., June 1, 2002; 165(11): 1504 - 1510.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online