Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 1176-1183, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farre, R.
Right arrow Articles by Navajas, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farre, R.
Right arrow Articles by Navajas, D.

Journal of Applied Physiology, Vol 76, Issue 3 1176-1183, Copyright © 1994 by American Physiological Society


ARTICLES

Human lung impedance from spontaneous breathing frequencies to 32 Hz

R. Farre, R. Peslin, M. Rotger and D. Navajas
Laboratori de Biofisica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Spain.

Lung impedance (ZL) was measured from 0.1875 to 32 Hz in spontaneously breathing healthy subjects by spectral analysis of the pressure and flow signals generated simultaneously by the muscular generator of breathing and by a forced oscillation system. This method did not require cooperation from the subject to perform panting or special ventilatory maneuvers and therefore allowed us to analyze the frequency dependence of lung resistance, reactance, and elastance (-2 pi.frequency.reactance) at the physiological conditions of normal breathing. Resistance and elastance parameters were also computed by multiple linear regression of the time-domain pressure and flow data on a simple resistance-elastance model. Resistances and elastances computed at the breathing frequency by spectral analysis and by multiple linear regression were similar (nonsignificant differences < 4 and 10%, respectively). The results obtained when comparing ZL from the breathing component (0.1875-0.75 Hz) of the recorded signals and from the forced oscillation component (2-32 Hz) were fairly consistent. ZL (0.1875-10 Hz) was interpreted in terms of a model consisting of an airway compartment, including a resistance and an inertance, in series with a viscoelastic tissue compartment (J. Hildebrandt. J. Appl. Physiol. 28: 365-372, 1970) characterized by two parameters. The model analysis provided parameter values (resistance 2.49 +/- 0.58 hPa.l-1.s, inertance 1.70 +/- 0.29 Pa.l-1.s2, Hildebrandt parameters 4.87 +/- 2.28 and 0.73 +/- 0.99 hPa/l) consistent with the hypothesis that lung tissue in healthy humans during spontaneous breathing behaves as a viscoelastic structure with a hysteresivity of approximately 0.10.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. Radegran and B. Saltin
Nitric oxide in the regulation of vasomotor tone in human skeletal muscle
Am J Physiol Heart Circ Physiol, June 1, 1999; 276(6): H1951 - H1960.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. NAVAJAS, R. FARRÉ, M. ROTGER, R. BADIA, M. P. de-MORALES, and J. M. MONTSERRAT
Assessment of Airflow Obstruction during CPAP by Means of Forced Oscillation in Patients with Sleep Apnea
Am. J. Respir. Crit. Care Med., May 1, 1997; 157(5): 1526 - 1530.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online