Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 1011-1013, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peslin, R.
Right arrow Articles by Duvivier, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peslin, R.
Right arrow Articles by Duvivier, C.

Journal of Applied Physiology, Vol 76, Issue 3 1011-1013, Copyright © 1994 by American Physiological Society


ARTICLES

Small-amplitude pressure oscillations do not modify respiratory mechanics in rabbits

R. Peslin, C. Saunier, C. Gallina and C. Duvivier
Unite 14 de Physiopathologie Respiratoire, Institut Natinal de la Sante et de la Recherche Medicale, Vandoeuvre-les-Nancy, France.

Changes in respiratory mechanics have occasionally been observed during high-frequency ventilation. In this study we investigated whether small pressure oscillations such as those used for respiratory impedance measurements modified total respiratory resistance (Rrs) and total respiratory elastance (Ers). The latter were measured in six paralyzed artificially ventilated rabbits with and without superimposed pressure oscillations at the airway opening. Rrs and Ers were obtained by least square fitting of low-pass filtered tracheal pressure and flow to the usual first-order model. Pressure oscillations of 2-4 hPa peak-to-peak at 10, 20, and 30 Hz applied for periods of 10 min had virtually no effect on Ers (changes ranging from -2.5 to 2.6%) and Rrs (0-8.2%). Analysis of variance did not show a significant difference on the pooled data. Pressure oscillations were also applied every other minute after a histamine aerosol. Ers and Rrs were similarly unchanged. We conclude that the small pressure oscillations used in respiratory impedance measurements do not modify lung mechanical properties and lung response to bronchomotor agents.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
A. M. LORINO, F. LOFASO, D. DUIZABO, F. ZERAH, F. GOLDENBERG, M. P. d'ORTHO, A. HARF, and H. LORINO
Respiratory Resistive Impedance as an Index of Airway Obstruction during Nasal Continuous Positive Airway Pressure Titration
Am. J. Respir. Crit. Care Med., November 1, 1998; 158(5): 1465 - 1470.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online