Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 76: 97-103, 1994;
8750-7587/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, B. P.
Right arrow Articles by Yang, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, B. P.
Right arrow Articles by Yang, M. H.

Journal of Applied Physiology, Vol 76, Issue 1 97-103, Copyright © 1994 by American Physiological Society


ARTICLES

Effects of pulmonary air embolism on discharge of slowly adapting pulmonary stretch receptors

B. P. Lee, H. F. Chen, F. C. Hsu, T. B. Kuo and M. H. Yang
Department of Physiology, National Yang-Ming Medical College, Taipei, Taiwan, Republic of China.

Pulmonary air embolism (PAE) usually causes small-airway collapse. Local transpulmonary pressure (Ptr) is thought to be closely associated with the activity of slowly adapting pulmonary stretch receptors (SAPSRs). To test whether discharge of SAPSRs located distal to collapsed airways is closely related to the overall Ptr, we studied 65 SAPSRs in anesthetized paralyzed open-chest dogs that were ventilated at constant tidal volume and frequency. PAE increased both Ptr and total pulmonary resistance but decreased dynamic lung compliance. Three groups of SAPSRs were identified on the basis of their locations in intrapulmonary airways. Group I had 29 SAPSRs located in airways < 1 mm in diameter. Group II had 10 SAPSRs that were found in intrapulmonary airways between 1 and 2 mm in diameter. PAE decreased the activity of 31 of the 39 SAPSRs in these two groups. Their activity during PAE was not related to Ptr. The 26 SAPSRs in group III were in airways > 2 mm in diameter. PAE increased the peak firing rate of 18 of these receptors, and there was a close relationship between the discharge frequency of these SAPSRs and the Ptr during PAE. In groups I and II, the dissociation between Ptr and SAPSR activity during PAE may have been caused by peripheral airway collapse. Activity of central fibers was blocked at higher temperatures than activity of peripheral fibers. We suggest that the response of a SAPSR to PAE depends on the location of the receptor within the lungs, and we speculate that threshold and fiber type are also related to location.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
H. F. Chen and Y. R. Kou
Vagal and mediator mechanisms underlying the tachypnea caused by pulmonary air embolism in dogs
J Appl Physiol, April 1, 2000; 88(4): 1247 - 1253.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
H. F. Chen, B. P. Lee, and Y. R. Kou
Mechanisms of stimulation of vagal pulmonary C fibers by pulmonary air embolism in dogs
J Appl Physiol, March 1, 1997; 82(3): 765 - 771.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online