Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 2142-2150, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sartene, R.
Right arrow Articles by Goldman, M. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sartene, R.
Right arrow Articles by Goldman, M. D.

Journal of Applied Physiology, Vol 75, Issue 5 2142-2150, Copyright © 1993 by American Physiological Society


ARTICLES

Comparison of thoracoabdominal calibration methods in normal human subjects

R. Sartene, C. Dartus, J. L. Bernard, M. Mathieu and M. D. Goldman
Service De Pneumologie, Hopital Robert Ballanger, Aulnay Sous Bois, France.

In 19 normal subjects in the supine posture, we compared accuracy and precision of calibration methods that utilized different ranges of tidal volumes and thoracoabdominal partitioning: spontaneous quiet breathing (QB), isovolume maneuvers, and voluntary efforts to breathe with variable tidal volume and thoracoabdominal partitioning. Thoracic and abdominal movements were measured with the respiratory area fluxometer. Calibration methods utilizing one or more types of respiratory efforts were applied to three measurement situations: QB, variable breathing (volume and thoracoabdominal partitioning), and simulated obstructive apnea (isovolume efforts). Qualitative diagnostic calibration (QDC) included QB data only. The isovolume method (ISOCAL) included isovolumetric efforts at end expiration (functional residual capacity) and QB. Multilinear regression analyses were performed on data sets that included 1) voluntary efforts to breathe with variable volume and thoracoabdominal partitioning (CAL 1), 2) QB in addition to variable volume and partitioning (CAL 2), and 3) isovolume maneuvers in addition to QB and variable volume and partitioning efforts (CAL 3). When calibration data included a wide range of tidal volume, variable thoracoabdominal partitioning, and isovolume efforts (CAL 3), a stable calibration with small bias and scatter during all respiratory patterns was obtained. Excluding isovolume maneuvers (CAL 2) and QB (CAL 1) did not diminish accuracy. Limiting data to isovolume efforts at functional residual capacity plus QB (ISO-CAL) caused a significant increase in scatter during variable breathing patterns. Limiting calibration data to that portion of QB with small variation in the uncalibrated sum of thoracic and abdominal movements (QDC) caused significant increases in scatter in both isovolume efforts and variable breathing.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
A. De Groote, M. Paiva, and Y. Verbandt
Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography
J Appl Physiol, March 1, 2001; 90(3): 1025 - 1030.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online