Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 1980-1983, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lin, Y.
Right arrow Articles by Jamieson, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lin, Y.
Right arrow Articles by Jamieson, D.

Journal of Applied Physiology, Vol 75, Issue 5 1980-1983, Copyright © 1993 by American Physiological Society


ARTICLES

Effect of humidity on hyperoxic toxicity

Y. Lin and D. Jamieson
School of Physiology and Pharmacology, University of New South Wales, Kensington, Australia.

Time to onset of hyperbaric oxygen-induced convulsions was measured in mice and rats exposed to hyperbaric oxygen (515-585 kPa) under conditions of low humidity (dry gas, < 10% relative humidity) or in a humidified environment (60% relative humidity). At all pressures tested, the duration of convulsive activity was markedly increased (P < 0.001), because of the earlier onset of severe generalized convulsions, in the groups of rodents exposed to the higher humidity. Pulmonary oxygen poisoning was determined by increases in lung wet and dry weights. Such pulmonary damage was also significantly (P < 0.001) increased in the humidified groups. Hyperoxic toxicity was also measured in rats and mice exposed to approximately 100% oxygen (normobaric hyperoxia) under conditions of 30 or 62% relative humidity. In contrast to the results obtained with hyperbaric oxygen exposure, there was slightly less toxicity in the rodents maintained at 62% compared with 30% humidity in normobaric hyperoxia.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. Arieli, G. Rashkovan, Y. Moskovitz, and O. Ertracht
PCO2 threshold for CNS oxygen toxicity in rats in the low range of hyperbaric PO2
J Appl Physiol, October 1, 2001; 91(4): 1582 - 1587.
[Abstract] [Full Text] [PDF]