Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 1930-1937, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stroman, P. W.
Right arrow Articles by Man, S. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stroman, P. W.
Right arrow Articles by Man, S. F.

Journal of Applied Physiology, Vol 75, Issue 5 1930-1937, Copyright © 1993 by American Physiological Society


ARTICLES

Evaluation of effects of PAF on alveolar fluid clearance with use of NMR imaging

P. W. Stroman, P. S. Allen, D. C. Lien, G. Machin and S. F. Man
Department of Applied Sciences in Medicine, University of Alberta, Edmonton, Canada.

Autologous serum with or without platelet-activating factor (PAF) was instilled into one lung lobe of an anesthetized cat, and changes in the regional lung water content were monitored for 4 h with proton nuclear magnetic resonance (NMR) images and relaxation time measurements. With serum as an instillate, water was cleared with a half time of approximately 670 min; after 4 h, 86 +/- 6% of that instilled remained. With PAF added to the instillate, clearance was biphasic with an initial clearance half time of approximately 30 min followed by clearance similar to that observed after serum instillation; after 4 h, 35 +/- 4% of that instilled remained. In contrast, 4 h after instillation of serum or serum plus PAF, 91 +/- 3% and 82 +/- 5%, respectively, of the instilled 125I-labeled albumin remained in the lung (P = 0.06). From transverse magnetization relaxation curves we were able to resolve two relaxation components, which we have attributed to the instilled fluid in the air spaces (relaxation time = 177 +/- 7 ms) and the tissue-bound fluid (relaxation time = 25 +/- 1 ms).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online