Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 1884-1889, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edwards, A. D.
Right arrow Articles by Reynolds, E. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edwards, A. D.
Right arrow Articles by Reynolds, E. O.

Journal of Applied Physiology, Vol 75, Issue 4 1884-1889, Copyright © 1993 by American Physiological Society


ARTICLES

Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy

A. D. Edwards, C. Richardson, P. van der Zee, C. Elwell, J. S. Wyatt, M. Cope, D. T. Delpy and E. O. Reynolds
Department of Paediatrics, University College and Middlesex School of Medicine, London, United Kingdom.

A noninvasive method of measuring hemoglobin flow through an organ by near-infrared spectroscopy (NIRS) is described that allows blood flow to be calculated. The method is derived from the Fick principle and uses a small change in arterial oxyhemoglobin concentration (brought about by a change in the fractional inspired O2 concentration) as an intravascular tracer. Changes in deoxyhemoglobin and oxyhemoglobin concentrations are quantified by monitoring variations in the absorption of near-infrared light in the organ, thus providing a measure of tracer accumulation. The tracer input function is calculated from the change in arterial O2 saturation, measured by pulse oximetry. The method was used to determine hemoglobin flow in the forearms of six healthy young adults on 10 occasions. Forearm hemoglobin flow ranged from 22.5 to 82.6 mumol.l-1.min-1. Calculated forearm blood flow ranged from 1.01 to 4.01 ml.100 g-1.min-1. For comparison, forearm blood flow was measured by venous occlusion plethysmography, and the relation between flow calculated by NIRS (y) and plethysmography (x) was y = 0.93x + 0.30 (r2 = 0.95). The mean difference between the methods was 0.14 ml.100 g-1.min-1. The technique may be widely applicable.


This article has been cited by other articles:


Home page
J. Physiol.Home page
D. W. Wray, P. J. Fadel, D. M. Keller, S. Ogoh, M. Sander, P. B. Raven, and M. L. Smith
Dynamic carotid baroreflex control of the peripheral circulation during exercise in humans
J. Physiol., September 1, 2004; 559(2): 675 - 684.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Kouzaki, M. Shinohara, K. Masani, M. Tachi, H. Kanehisa, and T. Fukunaga
Local blood circulation among knee extensor synergists in relation to alternate muscle activity during low-level sustained contraction
J Appl Physiol, July 1, 2003; 95(1): 49 - 56.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. A. Pigula, S. K. Gandhi, R. D. Siewers, P. J. Davis, S. A. Webber, and E. M. Nemoto
Regional low-flow perfusion provides somatic circulatory support during neonatal aortic arch surgery
Ann. Thorac. Surg., August 1, 2001; 72(2): 401 - 407.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. C. P. Van Beekvelt, W. N. J. M. Colier, R. A. Wevers, and B. G. M. Van Engelen
Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle
J Appl Physiol, February 1, 2001; 90(2): 511 - 519.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. Boushel, H. Langberg, J. Olesen, M. Nowak, L. Simonsen, J. Bulow, and M. Kjar
Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green
J Appl Physiol, November 1, 2000; 89(5): 1868 - 1878.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
O. S. Khalil
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Clin. Chem., February 1, 1999; 45(2): 165 - 177.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Chow, I. G. Roberts, A. D. Edwards, A. Lloyd-Thomas, A. Wade, M. J. Elliott, and F. J. Kirkham
THE RELATION BETWEEN PUMP FLOW RATE AND PULSATILITY ON CEREBRAL HEMODYNAMICS DURING PEDIATRIC CARDIOPULMONARY BYPASS
J. Thorac. Cardiovasc. Surg., October 1, 1997; 114(4): 568 - 577.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online