Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 1734-1739, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, P.
Right arrow Articles by Permutt, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, P., Jr
Right arrow Articles by Permutt, S.

Journal of Applied Physiology, Vol 75, Issue 4 1734-1739, Copyright © 1993 by American Physiological Society


ARTICLES

Influence of diffusion on estimations of protein reflection coefficient by double-indicator method

P. White Jr, R. G. Brower, J. T. Sylvester, T. Permutt and S. Permutt
Department of Medicine, Johns Hopkins Medical Institutions, Baltimore 21205.

In isolated perfused organs, vascular protein reflection coefficients (sigma) can be calculated from the changes in hematocrit and perfusate protein concentration (CP) that occur during edema formation. This technique requires the assumption that transvascular protein flux by diffusion is negligible. To assess diffusion-induced errors in calculations of sigma, we derived an expression for CP that includes determinants of diffusive protein flux: protein permeability-surface area product (PS), transvascular fluid flux (J), true sigma, and transvascular protein concentration. We used this expression to obtain values of CP under various experimental conditions and then calculated values of sigma (measured sigma) for those conditions. Diffusion causes measured sigma to be lower than true sigma. The diffusion-induced error is larger and potentially substantial when J/PS is low and when true sigma is high. Diffusion-induced error is also larger when the amount of edema formation is greater. In recent isolated canine lung experiments where J/PS was approximately 2.7, diffusion-induced errors in measured sigma for albumin would have been approximately 0.06 (at true sigma = 0.5) and approximately 0.18 (at true sigma = 0.9). When J/PS was higher, the potential for diffusion-induced errors was much smaller. We conclude that diffusion causes underestimation of true sigma and that the error in measured sigma may be substantial when J/PS is < 5 and when true sigma is > 0.5.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online