Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 75: 217-227, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Habib, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Habib, R.

Journal of Applied Physiology, Vol 75, Issue 1 217-227, Copyright © 1993 by American Physiological Society


ARTICLES

Branching airway network models for analyzing high-frequency lung input impedance

A. C. Jackson, B. Suki, M. Ucar and R. Habib
Biomedical Engineering Department, Boston University, Massachusetts 02215.

The input impedance of the lung (Zin) at high frequencies (> 100 Hz) is a complex function of the airway geometry and the mechanical properties of the airway walls. To investigate how the purely geometrical factors influence Zin, we measured Zin between 16 and 1,520 Hz in six dried dog lungs with the forced oscillation technique. In each of the lungs we found three resonances, at 36 +/- 5, 648 +/- 100, and 1,289 +/- 150 Hz, and at least two antiresonances (relative maxima in the real part of Zin), at 372 +/- 60 and 1,105 +/- 110 Hz. These data were fit with models featuring a detailed asymmetric branching network of the airways obtained from morphometric data published by Horsfield et al. (J. Appl. Physiol. 52: 21-26, 1982). On the basis of low-frequency (< 100 Hz) data alone, we first established a model of the acini, which was then attached to the end of the airway branching model. With a single scaling factor for the radius and length of the airways, the fit was unsatisfactory. Using sensitivity analysis techniques we determined which candidate variables of the structural model could influence Zin in a manner to improve the fit. We found that a two-parameter model accounting for separate central and peripheral airway diameter scaling provided a reasonable fit to Zin. On average the model required central diameter scaling close to unity (0.94 +/- 0.09), and the peripheral diameter scaling factor was 0.87 +/- 0.38. Over a range of parameter values that we believed were physiologically reasonable (i.e., scaling factors between 0.5 and 1.5), a single set of parameter values was found in all lungs. These results suggest that structurally based inverse models of Zin that include multiple antiresonances may provide information about airway geometry.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
Eur Respir JHome page
M. Henschen, J. Stocks, I. Brookes, and U. Frey
New aspects of airway mechanics in pre-term infants
Eur. Respir. J., May 1, 2006; 27(5): 913 - 920.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Suki, A. M. Alencar, J. Tolnai, T. Asztalos, F. Petak, M. K. Sujeer, K. Patel, J. Patel, H. E. Stanley, and Z. Hantos
Size distribution of recruited alveolar volumes in airway reopening
J Appl Physiol, November 1, 2000; 89(5): 2030 - 2040.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, K. MAKKONEN, T. WELLMAN, C. BEARDSMORE, and M. SILVERMAN
Alterations in Airway Wall Properties in Infants with a History of Wheezing Disorders
Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 1825 - 1829.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, M. SILVERMAN, R. KRAEMER, and A. C. JACKSON
High-frequency Respiratory Impedance Measured by Forced-Oscillation Technique in Infants
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 363 - 370.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. W. Thorpe and J. H. T. Bates
Effect of stochastic heterogeneity on lung impedance during acute bronchoconstriction: a model analysis
J Appl Physiol, May 1, 1997; 82(5): 1616 - 1625.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, B. Suki, R. Kraemer, and A. C. Jackson
Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations
J Appl Physiol, March 1, 1997; 82(3): 1018 - 1023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online