Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 74: 1206-1211, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stromberg, N. O.
Right arrow Articles by Gustafsson, P. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stromberg, N. O.
Right arrow Articles by Gustafsson, P. M.

Journal of Applied Physiology, Vol 74, Issue 3 1206-1211, Copyright © 1993 by American Physiological Society


ARTICLES

Evaluation of various models for respiratory inductance plethysmography calibration

N. O. Stromberg, G. O. Dahlback and P. M. Gustafsson
Department of Paediatrics, Faculty of Health Sciences, Linkoping University, Sweden.

We evaluated one nonlinear and two linear models of the ventilatory system while calibrating the respiratory inductance plethysmograph (RIP) against a pneumotachometer. A calibration method involving voluntary varying rib cage and abdominal contributions to tidal volume in a single body position was utilized. The influence on accuracy of the choice of respiratory phase during calibration was assessed. Both tidal and intratidal volumes were evaluated. Ten adults with no history of respiratory disorders went through RIP calibration and validation in the sitting and supine positions. A linear calibration model, relating lung volume changes from the start of inspiration or expiration to rib cage and abdominal excursions from initiation of respiratory motion, had the best accuracy. The choice of respiratory phase for calibration did not affect accuracy. RIP generally underestimated lung volume at the start of inspiration and overestimated lung volume at the end of inspiration. RIP was more accurate in the supine than the sitting position, probably because of limited spine flexion in the supine position.


This article has been cited by other articles:


Home page
JSLHRHome page
S. Collyer, C. W. Thorpe, J. Callaghan, and P. J. Davis
The Influence of Fundamental Frequency and Sound Pressure Level Range on Breathing Patterns in Female Classical Singing
J Speech Lang Hear Res, June 1, 2008; 51(3): 612 - 628.
[Abstract] [Full Text] [PDF]


Home page
Psychosom. Med.Home page
I. Van Diest, S. De Peuter, S. Devriese, E. Wellens, K. P. Van de Woestijne, and O. Van den Bergh
Imagined Risk of Suffocation as a Trigger for Hyperventilation
Psychosom Med, September 1, 2005; 67(5): 813 - 819.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C.-L. Que, C. Kolmaga, L.-G. Durand, S. M. Kelly, and P. T. Macklem
Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary results
J Appl Physiol, October 1, 2002; 93(4): 1515 - 1526.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online