Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 74: 1039-1044, 1993;
8750-7587/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peslin, R.
Right arrow Articles by Farre, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peslin, R.
Right arrow Articles by Farre, R.

Journal of Applied Physiology, Vol 74, Issue 3 1039-1044, Copyright © 1993 by American Physiological Society


ARTICLES

Validity of the esophageal balloon technique at high frequencies

R. Peslin, D. Navajas, M. Rotger and R. Farre
Laboratio Biofisica i Bioenginieria, Facultat de Medicina, Universitat de Barcelona, Spain.

The reliability of the esophageal balloon technique in measuring high-frequency changes in pleural pressure (Ppl) was investigated in six normal subjects by studying the amplitude ratio (A) and phase angle (phi) of esophageal (Pes) and mouth (Pm) pressures during airway occlusion and while pseudorandom pressure variations (2-32 Hz) were applied to the chest. The measurements were made with a common esophageal balloon-catheter system connected to a high-impedance piezoresistive transducer. When the cheeks were firmly supported, A averaged 1.08 +/- 0.063 at 2 Hz and 1.06 +/- 0.11 at 32 Hz. Pes increasingly led Pm with increasing frequency, and phi averaged 20.8 +/- 4.0 degrees at 32 Hz. Washing the airways with 80% He-20% O2 reduced phi by 50%. When the cheeks were not supported, A exhibited a strong positive frequency dependence, averaging 1.71 +/- 0.34 at 32 Hz, whereas phi increased much faster below 20 Hz and tended to decrease afterward. Because the esophageal transfer function Pes/Ppl = (Pes/Pm)/(Ppl/Pm), we could estimate Pes/Ppl by computing for individual subjects the pressure difference between the pleura and the mouth based on the lung and upper airway wall properties that were measured separately. The results suggest that the ratio of Pes and Ppl remains close to unity from 2 to 32 Hz, but Pes lags slightly behind Ppl (phi equals about -7 degrees at 32 Hz).


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
L. D. Black, R. Dellaca, K. Jung, H. Atileh, E. Israel, E. P. Ingenito, and K. R. Lutchen
Tracking variations in airway caliber by using total respiratory vs. airway resistance in healthy and asthmatic subjects