Journal of Applied Physiology, Vol 74, Issue 1 203-210, Copyright © 1993 by American Physiological Society
ARTICLES |
I. Kuwahira, N. C. Gonzalez, N. Heisler and J. Piiper
Abteilung Physiologie, Max-Planck-Institut fur experimentelle Medizin, Gottingen, Federal Republic of Germany.
To determine organ blood flow in the resting state, a box was designed to keep conscious untrained rats minimally disturbed. Blood pressure, heart rate, and organ blood flow, determined by the microsphere distribution and reference sampling technique, were measured in 11 Sprague-Dawley rats. After an acclimation period, 15-microns-diameter microspheres labeled with 113Sn were infused into the ascending aorta, a reference blood sample was withdrawn from the caudal artery, and organ blood flows were computed according to standard procedures. The average values of heart rate (365 beats/min) and blood flow to the brain (45 ml.min-1.100 g-1) and hindlimb muscles (15 ml.min-1.100 g-1) were significantly lower than most values reported earlier, whereas splanchnic blood flow was significantly higher (106 ml.min-1.100 g-1). Blood flow to the soleus muscle, which is considered the most active for postural maintenance, was relatively high (99 ml.min-1.100 g-1). The combination of low skeletal muscle and high visceral blood flows observed in these experiments suggests a low sympathetic tone, which is consistent with the low level of circulating catecholamines also observed in this study. It is hypothesized that the difference between our present and previous results is a lower level of stress, attributable to a more complete acclimation to the experimental environment.
This article has been cited by other articles:
![]() |
D. Ricart-Jane, P. Cejudo-Martin, J. Peinado-Onsurbe, M. D. Lopez-Tejero, and M. Llobera Changes in lipoprotein lipase modulate tissue energy supply during stress J Appl Physiol, October 1, 2005; 99(4): 1343 - 1351. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Ogihara, W. Kawamura, K. Kasuga, Y. Hayashi, H. Arakawa, and M. Kikuchi Characterization of the portal signal during 24-h glucose delivery in unrestrained, conscious rats Am J Physiol Endocrinol Metab, June 1, 2004; 286(6): E932 - E940. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Nestorov, I. Gueorguieva, H. M. Jones, B. Houston, and M. Rowland Incorporating Measures of Variability and Uncertainty into the Prediction of in Vivo Hepatic Clearance from in Vitro Data Drug Metab. Dispos., March 1, 2002; 30(3): 276 - 282. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Glenny, S. L. Bernard, and W. J. Lamm Hemodynamic effects of 15-{micro}m-diameter microspheres on the rat pulmonary circulation J Appl Physiol, August 1, 2000; 89(2): 499 - 504. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Kuwahira, U. Kamiya, T. Iwamoto, Y. Moue, T. Urano, Y. Ohta, and N. C. Gonzalez Splenic contraction-induced reversible increase in hemoglobin concentration in intermittent hypoxia J Appl Physiol, January 1, 1999; 86(1): 181 - 187. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |