Journal of Applied Physiology Millar Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 73: 1820-1824, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ishizaka, A.
Right arrow Articles by Kawashiro, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ishizaka, A.
Right arrow Articles by Kawashiro, T.

Journal of Applied Physiology, Vol 73, Issue 5 1820-1824, Copyright © 1992 by American Physiological Society


ARTICLES

Influence of chest background on pulmonary 99mTc-DTPA clearance in interstitial lung disease

A. Ishizaka, M. Kanazawa, Y. Suzuki, N. Hasegawa, A. Kubo and T. Kawashiro
Department of Medicine, School of Medicine, Keio University, Tokyo, Japan.

We examined the effect of chest extracellular 99mTc-diethylenetriamine pentaacetate (DTPA) as a background in the measurement of pulmonary 99mTc-DTPA clearance in patients with interstitial lung disease (ILD). Eight healthy nonsmokers (HN) and eight patients with ILD were studied. We monitored changes in gamma counts after the inhalation of 99mTc-DTPA aerosol by using a gamma camera placed over the anterior chest. The rate constant of pulmonary 99mTc-DTPA clearance (k; %/min) was assessed by calculating the slope of the decrease in the gamma counts. The chest background, estimated by 99mTc-DTPA intravenous injection, was subtracted from the original data to obtain the corrected DTPA clearance (kc; %/min). In patients with ILD, k was significantly greater [2.19 +/- 1.03 (SD) %/min; n = 8] compared with HN (0.86 +/- 0.17%/min; n = 8; P < 0.01). In patients with ILD, kc was also greater (2.80 +/- 1.15%/min; n = 8; P < 0.01) compared with HN (1.20 +/- 0.12%/min; n = 8). There was no difference in percent underestimation of k between the two groups (29.1 +/- 8.8% for HN, 22.5 +/- 7.9% for patients with ILD). There was a significant correlation between k and kc among all subjects (r = 0.987, P < 0.01). We conclude that background causes significant underestimation of pulmonary 99mTc-DTPA clearance.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online