Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 73: 276-283, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vilstrup, C. T.
Right arrow Articles by Werner, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vilstrup, C. T.
Right arrow Articles by Werner, O.

Journal of Applied Physiology, Vol 73, Issue 1 276-283, Copyright © 1992 by American Physiological Society


ARTICLES

Functional residual capacity and ventilation homogeneity in mechanically ventilated small neonates

C. T. Vilstrup, L. J. Bjorklund, A. Larsson, B. Lachmann and O. Werner
Department of Anesthesia, University Hospital, Lund, Sweden.

A modification of a computerized tracer gas (SF6) washout method was designed for serial measurements of functional residual capacity (FRC) and ventilation homogeneity in mechanically ventilated very-low-birth-weight infants with tidal volumes down to 4 ml. The method, which can be used regardless of the inspired O2 concentration, gave accurate and reproducible results in a lung model and good agreement compared with He dilution in rabbits. FRC was measured during 2-4 cmH2O of positive end-expiratory pressure (PEEP) in 15 neonates (700-1,950 g), most of them with mild-to-moderate respiratory distress syndrome. FRC increased with body weight and decreased (P less than 0.05) with increasing O2 requirement. Change to zero end-expiratory pressure caused an immediate decrease in FRC by 29% (P less than 0.01) and gave FRC (ml) = -1.4 + 17 x weight (kg) (r = 0.83). Five minutes after PEEP was discontinued (n = 12), FRC had decreased by a further 16% (P less than 0.01). The washout curves indicated a near-normal ventilation homogeneity not related to changes in PEEP. This was interpreted as evidence against the presence of large volumes of trapped alveolar gas.


This article has been cited by other articles:


Home page
Eur Respir JHome page
A. Schibler, G.L. Hall, F. Businger, B. Reinmann, J.H. Wildhaber, M. Cernelc, and U. Frey
Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Eur. Respir. J., October 1, 2002; 20(4): 912 - 918.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
A Schibler and U Frey
Role of lung function testing in the management of mechanically ventilated infants
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2002; 87(1): F7 - 10.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
M Mazzella, C Bellini, M G Calevo, F Campone, D Massocco, P Mezzano, E Zullino, F Scopesi, C Arioni, W Bonacci, et al.
A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infants
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2001; 85(2): F86 - 90.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. THOME, A. TOPFER, P. SCHALLER, and F. POHLANDT
Effect of Mean Airway Pressure on Lung Volume during High-frequency Oscillatory Ventilation of Preterm Infants
Am. J. Respir. Crit. Care Med., April 1, 1998; 157(4): 1213 - 1218.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online