Journal of Applied Physiology Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 72: 535-542, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grant, B. J.
Right arrow Articles by Lieber, B. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grant, B. J.
Right arrow Articles by Lieber, B. B.

Journal of Applied Physiology, Vol 72, Issue 2 535-542, Copyright © 1992 by American Physiological Society


ARTICLES

Compliance of the main pulmonary artery during the ventilatory cycle

B. J. Grant and B. B. Lieber
Department of Medicine, State University of New York, Buffalo 14215.

Transmural pulmonary arterial pressure (Ppa), diameter (D), and length (L) of a segment of the main pulmonary artery (MPA) were measured simultaneously in anesthetized open-chest dogs. The instantaneous volume was calculated from D and L. Pulmonary arterial elasticity for diameter (EpD) was calculated as the ratio of the amplitude of Ppa to D oscillation normalized by the mean D. Similar indexes were calculated for L (EpL) and V (Epv). Compliance per unit length was calculated from the dimensions and elasticity of the MPA. Under control conditions with 5 cmH2O positive end-expiratory pressure, EpD, EpL, and Epv at cardiac frequency were 175 +/- 27, 147 +/- 27, and 55 +/- 7 cmH2O, respectively. EpD increased with positive end-expiratory pressure, but EpL decreased and Epv was unaffected. EpD, EpL, Epv, and compliance per unit length were not significantly different between the start of inspiration and the start of expiration. In addition, there were no significant phase differences between the oscillations of Ppa and V at respiratory frequency. We conclude that the previously reported time variation of pulmonary arterial compliance during the ventilatory cycle is not due to time-varying properties of the MPA.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online