Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 72: 46-52, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bates, J. H.
Right arrow Articles by Hantos, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bates, J. H.
Right arrow Articles by Hantos, Z.

Journal of Applied Physiology, Vol 72, Issue 1 46-52, Copyright © 1992 by American Physiological Society


ARTICLES

A comparison of interrupter and forced oscillation measurements of respiratory resistance in the dog

J. H. Bates, B. Daroczy and Z. Hantos
Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.

We compared the values of resistance produced by the forced oscillation technique (FOT) and the flow interruption technique (IT) when applied to six anesthetized paralyzed tracheostomized dogs. The FOT returned values of respiratory system resistance as a function of frequency [Re(f)] between 0.25 and 20 Hz. The IT returned a single value of resistance (Rinit) calculated by dividing the immediate change in tracheal pressure occurring upon interruption by the preinterruption flow. We found Rinit to coincide closely with Re(f) in the frequency range 5-20 Hz. Rinit has previously been interpreted as the high-frequency resistance of a resistance-elastance model of the respiratory system airways and tissues. It has also been shown previously, by direct measurement of alveolar pressure in dogs, that Rinit from the lungs alone is an accurate measure of airways resistance while Rinit obtained from the total respiratory system equals airways resistance plus a modest contribution from the chest wall. Re(f) at a frequency of approximately 10 Hz thus appears to be a useful quantity to measure as an index of airways resistance in the dog.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
J. Immunol.Home page
K. Kitagaki, T. R. Businga, D. Racila, D. E. Elliott, J. V. Weinstock, and J. N. Kline
Intestinal Helminths Protect in a Murine Model of Asthma
J. Immunol., August 1, 2006; 177(3): 1628 - 1635.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Babik, F. Petak, T. Asztalos, Z.I. Deak, G. Bogats, and Z. Hantos
Components of respiratory resistance monitored in mechanically ventilated patients
Eur. Respir. J., December 1, 2002; 20(6): 1538 - 1544.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online