Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 72: 231-235, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Panizza, J. A.
Right arrow Articles by Finucane, K. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Panizza, J. A.
Right arrow Articles by Finucane, K. E.

Journal of Applied Physiology, Vol 72, Issue 1 231-235, Copyright © 1992 by American Physiological Society


ARTICLES

Comparison of balloon and transducer catheters for estimating lung elasticity

J. A. Panizza and K. E. Finucane
Department of Pulmonary Physiology, Sir Charles Gairdner Hospital, Nedlands, Western Australia.

Pleural pressure is usually estimated with a balloon catheter (BC) positioned in the middle third of the esophagus. An alternate method, which avoids potential inaccuracies associated with changes in balloon volume, is a catheter-mounted transducer (CMT) system. To assess the accuracy of a CMT system in defining the elastic properties of the lungs, we compared the static pressure-volume (PV) properties of the lungs measured sequentially with CMT and BC systems in six healthy subjects each on two occasions, relating static transpulmonary pressure (Pst,L) to lung volume during interrupted exhalations from total lung capacity (TLC). PV data were fitted with an exponential function (least-squares method), and the exponent (k) was used to define the shape of the PV curve; position was defined by Pst,L at TLC and at 90 and 60% TLC. These data were examined for agreement (paired t test) and repeatability (coefficient of repeatability). No significant differences were demonstrated: k was 0.10 +/- 0.02 and 0.11 +/- 0.03 (SD) and Pst,L at 60% TLC was 8.27 +/- 2.09 and 8.37 +/- 1.63 cmH2O for the CMT and BC systems, respectively. The coefficient of repeatability for each parameter was not significantly different but was consistently less with the BC, suggesting better repeatability. We conclude that a CMT system is an acceptable alternative to a BC system for defining the elastic properties of lungs.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
D. Bettinelli, C. Kays, O. Bailliart, A. Capderou, P. Techoueyres, J. L. Lachaud, P. Vaida, and G. Miserocchi
Effect of gravity and posture on lung mechanics
J Appl Physiol, December 1, 2002; 93(6): 2044 - 2052.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. Pankow, T. Podszus, T. Gutheil, T. Penzel, J.-H. Peter, and P. Von Wichert
Expiratory flow limitation and intrinsic positive end-expiratory pressure in obesity
J Appl Physiol, October 1, 1998; 85(4): 1236 - 1243.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online