Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 72: 186-193, 1992;
8750-7587/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Colebatch, H. J.
Right arrow Articles by Maccioni, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Colebatch, H. J.
Right arrow Articles by Maccioni, F. J.

Journal of Applied Physiology, Vol 72, Issue 1 186-193, Copyright © 1992 by American Physiological Society


ARTICLES

Effect of the chest wall and blood volume on pulmonary distensibility

H. J. Colebatch, C. K. Ng, N. Berend and F. J. Maccioni
Department of Medicine, University of New South Wales, Prince Henry Hospital, Australia.

To determine the reason for increased pulmonary distensibility in excised lungs, we performed deflation pressure-volume (PV) studies in 24 dogs. Exponential analysis of PV data gave K, an index of distensibility. Lung volume was measured by dilution of neon. Compared with measurements obtained in the supine position, with the chest closed, and with esophageal pressure (Pes) to obtain transpulmonary pressure, K was not changed significantly with the chest strapped, with pleural pressure to obtain transpulmonary pressure, or with the chest open. From displacement of PV curves obtained in the supine position and with the chest closed or open, we estimated that Pes was 0.18 kPa greater than average lung surface pressure. An increase in K in the prone and head-up positions was attributed to a traction artifact decreasing Pes. Exsanguination increased K and produced a relative increase in gas volume. These results show that overall pulmonary distensibility is unaffected by an intact chest wall. An increase in K and gas volume after exsanguination probably reflects a decreased pulmonary blood volume, with collapse of capillaries increasing the alveolar volume-to-surface ratio.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
J. Verheij, A. van Lingen, P. G. H. M. Raijmakers, E. R. Rijnsburger, D. P. Veerman, W. Wisselink, A. R. J. Girbes, and A. B. J. Groeneveld
Effect of fluid loading with saline or colloids on pulmonary permeability, oedema and lung injury score after cardiac and major vascular surgery
Br. J. Anaesth., January 1, 2006; 96(1): 21 - 30.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
I Schulze-Neick, D J Penny, G P Derrick, R Dhillon, M L Rigby, A Kelleher, A Bush, and A N Redington
Pulmonary vascular-bronchial interactions: acute reduction in pulmonary blood flow alters lung mechanics
Heart, September 1, 2000; 84(3): 284 - 289.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. M. Walther, K. B. Domino, R. W. Glenny, N. L. Polissar, and M. P. Hlastala
Pulmonary blood flow distribution has a hilar-to-peripheral gradient in awake, prone sheep
J Appl Physiol, February 1, 1997; 82(2): 678 - 685.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online