Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 71: 698-702, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lands, L. C.
Right arrow Articles by Webber, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lands, L. C.
Right arrow Articles by Webber, C. E.

Journal of Applied Physiology, Vol 71, Issue 2 698-702, Copyright © 1991 by American Physiological Society


ARTICLES

Accuracy of measurements of small changes in soft tissue mass by use of dual-photon absorptiometry

L. C. Lands, G. J. Heigenhauser, C. Gordon, N. L. Jones and C. E. Webber
Ambrose Cardiorespiratory Unit, Department of Medicine, McMaster University, Hamilton, Ontario, Canada.

Dual-photon absorptiometry (DPA) has recently been applied to the assessment of body composition. To evaluate the accuracy of DPA in detecting small changes in the lean soft tissue mass, we performed DPA with the use of the Norland 2600 Dichromatic densitometer on six healthy adult males before and after a 30-ml/kg transfusion of saline and before and after exercise in a warm environment, resulting in a greater than or equal to 1-kg weight loss. Absolute weight [baseline pretransfusion r2 = 0.999, standard error of estimate (SEE) = 590 g; posttransfusion r2 = 0.999, SEE = 300 g; baseline pretranspiration r2 = 0.999, SEE = 230 g; posttranspiration r2 = 0.999, SEE = 240 g] was accurately reflected in DPA total mass. Weight changes due to transfusion were poorly reflected by changes in DPA total mass (r2 = 0.417, SEE = 404 g). However, changes posttranspiration were accurately reflected in the DPA total mass (r2 = 0.886, SEE = 106 g posttranspiration). Similarly, weight changes due to transfusion were poorly measured by changes in DPA soft mass (r2 = 0.478, SEE = 365 g), but changes posttranspiration were highly correlated with DPA soft mass changes (r2 = 0.909, SEE = 92 g). Weight changes were not reflected by changes in the DPA lean soft tissue mass (r2 = 0.006, SEE = 1,737 posttransfusion, r2 = 0.094, SEE = 1,038 g posttranspiration). DPA-derived nonfat mass was highly correlated with skinfold-derived nonfat mass (r2 = 0.96, SEE = 2,400 g). Accuracy of total and soft tissue measurements implied correct mineral mass assessment.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
A. Pietrobelli, Z. Wang, C. Formica, and S. B. Heymsfield
Dual-energy X-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration
Am J Physiol Endocrinol Metab, May 1, 1998; 274(5): E808 - E816.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online