Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 71: 60-68, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tikuisis, P.
Right arrow Articles by Radomski, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tikuisis, P.
Right arrow Articles by Radomski, M. W.

Journal of Applied Physiology, Vol 71, Issue 1 60-68, Copyright © 1991 by American Physiological Society


ARTICLES

Heat debt during cold air exposure before and after cold water immersions

P. Tikuisis, D. H. McCracken and M. W. Radomski
Defence and Civil Institute of Environmental Medicine, University of Toronto, Ontario, Canada.

Acclimation to cold can manifest itself in several different ways, insulative and metabolic being the most common. Bittel (J. Appl. Physiol. 62: 1627-1634, 1987) has demonstrated that heat debt, which encompasses both heat production and heat loss, can be used as a unitary index of acclimation. However, conflicting results are obtained if heat debt is calculated using a mean-weighted body temperature (Tb) vs. the change of body heat content through the integration of heat storage (S). The present study examines the determination of heat debt by three methods of calculation, the first based on Tb and the other two based on S where heat losses are measured in one and predicted in the other. Data were obtained from five healthy young males exposed to 10 degrees C air for 2 h on four different occasions. The first two exposures provided control data, while the last two were performed after 5 and 10 days, respectively, of daily immersions in 15 degrees C water to induce acclimation. The variability in response between the control exposures was as large as that among the other exposures. Although the method of calculation using Tb indicated that subjects were close to a thermal balance after 2 h of cold air exposure, this contrasted sharply with the result of the other two methods that indicated heat debt was still increasing steadily. The latter two methods are considered more accurate for transient heat debt calculation. Although cases of individual acclimation were found, these were different among the subjects, resulting in pooled responses that indicated no group acclimation by means of any of the three methods of calculation.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
J. W. Castellani, A. J. Young, C. O'Brien, D. A. Stulz, M. N. Sawka, and K. B. Pandolf
Cold strain index applied to exercising men in cold-wet conditions
Am J Physiol Regulatory Integrative Comp Physiol, December 1, 2001; 281(6): R1764 - R1768.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online