Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 2514-2521, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaise, A.
Right arrow Articles by Mitzner, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaise, A.
Right arrow Articles by Mitzner, W.

Journal of Applied Physiology, Vol 70, Issue 6 2514-2521, Copyright © 1991 by American Physiological Society


ARTICLES

Interaction between CO2 concentration and flow rate on peripheral airway resistance

A. Kaise, A. N. Freed and W. Mitzner
Department of Environmental Health Sciences, Johns Hopkins University, Baltimore, Maryland 21205.

In the present study, we investigated the interaction between CO2 concentration and rate of delivered flow on peripheral airway resistance (Rp) in the intact canine lung. Dogs were anesthetized, intubated, paralyzed, and mechanically ventilated with room air to maintain end-tidal CO2 between 4.8 and 5.2%. Using a wedged bronchoscope technique, we measured Rp at functional residual capacity. The relationship between CO2 concentration and Rp was measured at flow rates of 100 and 400 ml/min with 5, 3, 2, 1, and 0% CO2 in air. Measurements were made at the end of a 3-min exposure to each gas. At low flow rates (100 ml/min) responses to hypocapnia were small, whereas at high flow rates (400 ml/min) responses were large. The PC50 (defined as the CO2 concentration required to produce a 50% increase in Rp above baseline Rp established on 5% CO2) at 400 ml/min (1.73%) was significantly larger than that at 100 ml/min (0.38%). We also directly measured the relationship between Rp and flow rate with 5% CO2 (normocapnia) or 1% CO2 (hypocapnia) delivered into the wedged segment. Increases in normocapnic flow caused small but significant decreases in Rp. In contrast, increases in hypocapnic flow from 100 to 400 ml/min caused a 108% increase in Rp. Thus the response to hypocapnia is augmented by increasing flow rate. This interaction can be explained by a simple model that considers the effect of local ventilation-perfusion ratio and gas mixing on the local CO2 concentration at the site of peripheral airway contraction.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
W. Mitzner
Airway Smooth Muscle: The Appendix of the Lung
Am. J. Respir. Crit. Care Med., April 1, 2004; 169(7): 787 - 790.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Simon, K. Tsuzaki, and J. G. Venegas
Changes in regional lung mechanics and ventilation distribution after unilateral pulmonary artery occlusion
J Appl Physiol, March 1, 1997; 82(3): 882 - 891.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online