Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 2193-2205, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mercer, R. R.
Right arrow Articles by Crapo, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mercer, R. R.
Right arrow Articles by Crapo, J. D.

Journal of Applied Physiology, Vol 70, Issue 5 2193-2205, Copyright © 1991 by American Physiological Society


ARTICLES

Inhomogeneity of ventilatory unit volume and its effects on reactive gas uptake

R. R. Mercer, S. Anjilvel, F. J. Miller and J. D. Crapo
Department of Medicine, Duke University Medical Center, Durham, North Carolina 27710.

This study addressed the question of whether variations in the volume of alveoli and alveolar ducts forming single units of ventilation can significantly influence the distribution and uptake of inspired reactive gases. Quantitative serial section analyses of vascular perfusion-fixed rat lungs were used to determine the anatomic dead space proximal to specific ventilatory units as well as the gas volume of these ventilatory units. Three reconstructions, each consisting of ventilatory units distal to a specific bronchus, were carried out. The number of ventilatory units for each reconstruction varied from 26 to 71. The average ventilatory unit volume for the three reconstructions [0.53 +/- .03 (SE) mm3] was not significantly different from measurements based on random sampling. The distribution of ventilatory unit volume was diverse, with 15% of the population having a volume less than 0.3 mm3 and 9% of the population having a volume greater than 1.0 mm3. For a gas of relatively low reactivity (e.g., oxygen) the predicted oxygen uptake per unit surface area did not vary significantly between ventilatory units. The predicted oxygen uptake was approximately 92% of the uptake in the absence of gradients in oxygen concentration between ventilatory units. For a highly reactive gas (e.g., ozone), the predicted uptake per unit surface area in the proximal portions of larger ventilatory units was significantly greater than the average uptake. These results suggest that focal areas of injury likely result from exposure to inhaled reactive gases.


This article has been cited by other articles:


Home page
Toxicol SciHome page
W. Hofmann, B. Asgharian, R. Bergmann, S. Anjilvel, and F. J. Miller
The Effect of Heterogeneity of Lung Structure on Particle Deposition in the Rat Lung
Toxicol. Sci., February 1, 2000; 53(2): 430 - 437.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online