Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 2188-2192, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jaeger, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jaeger, M. J.

Journal of Applied Physiology, Vol 70, Issue 5 2188-2192, Copyright © 1991 by American Physiological Society


ARTICLES

High-frequency ventilation in dogs with three gases of different densities

M. J. Jaeger
Department of Physiology, College of Medicine, University of Florida, Gainesville 32610.

Dogs were ventilated with a high-frequency oscillation device varying the frequency (5-15 Hz), the tidal volume (25-100 ml), and the resident gas (He, N2, SF6). Tidal volume was measured with a body plethysmograph. Blood gases were measured after a quasi-steady state was established. The kinematic viscosity of the breathing gas mixture, which changed by 1,700%, was found to have little effect on arterial PO2 and PCO2. The results are consistent with findings in a branched model that consisted of tubes with a diameter of 1 cm and with the theory of Taylor-type diffusion in turbulent flow. In addition, experiments were performed reducing and increasing the equipment dead space. This resulted in changes of PO2 and PCO2 that were appreciably less than those resulting from variations of tidal volume of the same magnitude.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
A. KATZ, M. A. GENTILE, D. M. CRAIG, G. QUICK, J. N. MELIONES, and I. M. CHEIFETZ
Heliox Improves Gas Exchange during High-frequency Ventilation in a Pediatric Model of Acute Lung Injury
Am. J. Respir. Crit. Care Med., July 15, 2001; 164(2): 260 - 264.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online